background image

5

ROBATA 72/54 CONCRETE FIRE CE Match-lit | Installation & Owner’s Manual

DIMENSIONS - ROBATA 72

SIDE

END

BOTTOM

BASE OPENINGS

VENTILATION GAPS

DO NOT OBSTRUCT

12-1/2”

318

16-3/4”

425

24”

610

72”

1829

22”

559

11-1/4”

286

Summary of Contents for ROBATA 54 CORTEN FIRE

Page 1: ...ce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper tent car or home WARNING Improper installation adjustment...

Page 2: ...fixed piping system The installation must conform to local and or national codes 3 Never leave the fire unattended 4 Keep the appliance area clear and free from combustible materials gasoline and othe...

Page 3: ...TOPPING TRAY GAS SUPPLY BODY CONTROL KEY ROBATA 72 ROBATA 54 1 UNPACK Account for all parts p 15 16 2 FRAGILE Handle with care 3 LEVEL Place on a solid level surface 4 AIR VENTS Do not block ventilat...

Page 4: ...2 54 CONCRETE FIRE CE Match lit Installation Owner s Manual DIMENSIONS ROBATA 54 SIDE END BOTTOM VENTILATION GAP DO NOT OBSTRUCT BASE OPENING 22 559 24 610 54 1372 20 3 4 527 12 1 2 318 22 559 12 1 2...

Page 5: ...BATA 72 54 CONCRETE FIRE CE Match lit Installation Owner s Manual DIMENSIONS ROBATA 72 SIDE END BOTTOM BASE OPENINGS VENTILATION GAPS DO NOT OBSTRUCT 12 1 2 318 16 3 4 425 24 610 72 1829 22 559 11 1 4...

Page 6: ...AS ROBATA 72 PROPANE Burner Model LIN E 36 LIN E 36P LIN E 48 LIN E 48P Heat Input G20 20 mbar 20 kW G31 37 mbar 18 kW 1210 gr h G20 20 mbar 27 kW G31 37 mbar 25 kW 1758 gr h Burner Pressure 8 7 mbar...

Page 7: ...and evenly distribute decorative topping media lava rock or tempered glass pebble on top of burner media See page 8 Decorative media should be brought level with the top of the pilot cover An uneven o...

Page 8: ...lit Installation Owner s Manual BURNER MEDIA DECORATIVE TOPPING METAL LID OPTIONAL DECORATIVE TOPPING MEDIA VARIOUS FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS...

Page 9: ...el pressures Pipes of a smaller size than the heater inlet gas connection must not be used If utilizing used pipe verify that its condition is clean and comparable to a new pipe Test all gas supply li...

Page 10: ...ualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or...

Page 11: ...n air may require forced ventilation 2 Push knob slightly and turn the gas control knob to the PILOT position 3 Push down on the gas control knob and light the pilot immediately by applying a flame to...

Page 12: ...leshooting guide page 13 BURNER ELEMENT AND PILOT Keep the burner and pilot area clean by vacuuming or brushing at least twice a year Make sure the burner porting and burner air openings are free of o...

Page 13: ...ne 2 Check reset gas regulator pressure Gas odor even when manual valve is in the OFF position 1 Gas leak See Warning statement below 2 Main gas valve defective 1 Locate and correct all leaks see Chec...

Page 14: ...37 or 43 4 Media Tray LIN 36 or 48 ASSY A same 5 Burner Tray LIN 36 or 48 ASSY B same 6 Pilot Assembly PIL M 388 PIL M 388LP 7 Valve Bracket Standoff M VB A63 SO L same 8 Valve Bracket M VB A63 same...

Page 15: ...l also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembly damaged by accident...