background image

14

MISO 48 FIREBOWL Electronic Ignition | Installation & Owner's Manual

ILLUSTRATED PARTS LIST

Natural Gas

Propane

1

Pilot Cover

CIR-EPC

same

1a

Pilot Shroud

CIR-EPC

same

2

Pilot Assembly

PIL-E-410

PIL-E-410LP

3

18” Burner Ring

CIR-24-BUR

same

4

Burner Pan

CIR-24-PAN

same

5

Venturi

CIR-VEN-1

same

5a

Air Shutter

-

-

6

Orifice

FIT-ORI-J

FIT-ORI-27

7

3/8” Flare Adapter

-

-

8

Flex Connector

CON-SS-5MM-12

same

9

CIR Control Box

see drawing

same

10

Control Box Chassis

CIR-E-CHA

same

11

Power Adapter 120V-NA 

(not shown)

E-POW-24VAC

same

12

Burner Media (not shown)

Crushed Glass 25 kg

Lava Pebbles 18 L

13

Topping Media (not shown)

Various

Various

14

Fabric Cover (not shown)

COV-MIS48-LC

same

15

Concrete Vessel (not shown)

MIS48-(colour code)

same

WARNING: Failure to position parts in accordance with diagrams or failure 

to use parts specifically approved for this appliance may result in property 

damage or personal injury.

REPLACEMENT PARTS ARE AVAILABLE FROM PALOFORM

1

1a

2

3

4

5

5a

6

7

8

9

10

Summary of Contents for MISO 48

Page 1: ...WARNING FOR OUTDOOR USE ONLY Installation and service must be performed by a qualified installer service agency or gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this man...

Page 2: ...Code ANSI Z223 1 NFPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fue...

Page 3: ...S ELECTRICAL 1 UNPACK Account for all parts see p 14 2 FRAGILE Handle with care 3 LEVEL Place on a solid level surface 4 AIR VENTS Do not block ventilation holes in base see p 4 5 GAS ELECTRICAL Suppl...

Page 4: ...R E 24 CIR E 24P Max Heat Input 140 000 BTU h 140 000 BTU h Inlet Pressure Min 4 5 W C 11 0 W C Inlet Pressure Max 10 5 W C 13 0 W C Orifice Size J 27 Burner Ports 114 114 Port Size 1 8 1 8 Electrical...

Page 5: ...5 MISO 48 FIREBOWL Electronic Ignition Installation Owner s Manual FIG 1 MINIMUM CLEARANCES TO COMBUSTIBLES REQUIRED CLEARANCES 82 11 0 CLEARANCE BELOW...

Page 6: ...ult in an uneven flame 6 Do not cover pilot shield Keep the lighting port open and free of media Do not use any media not supplied by the manufacturer BURNER MEDIA DECORATIVE TOPPING IGNITION PORT DO...

Page 7: ...S FILL TOPPING TRAY COVER BURNER MEDIA KEEP BELOW LID LINE BURNER MEDIA CRUSHED GLASS NG or LAVA ROCK LP FILL BURNER MEDIA TRAY COMPLETELY COVER BURNER RING VENTILATION HOLES DO NOT BLOCK CAUTION Do n...

Page 8: ...an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressu...

Page 9: ...lified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Improper installation adjustment alteration service or ma...

Page 10: ...manual gas control valve to the ON position 7 Plug the supplied 24 VAC AC adapter into a 110V power outlet 8 Connect the AC adapter to the AC input plug at the unit 9 Place Burner Assembly in Housing...

Page 11: ...least twice a year Keep the burner and pilot area clean by vacuuming or brushing Make sure the burner porting and burner air openings are free of obstructions at all times Remove pilot cover to inspec...

Page 12: ...ITION PORT In the case of consistently windy conditions a protective glass barrier may be necessary 2 Ensure gas line is thoroughly bled 3 Ensure ventilation holes gaps are not obstructed Unit is smok...

Page 13: ...clogged 4 Pilot valve lead is loose disconnected 1 Turn off gas supply or open manual shutoff valve 2 Purge air from the supply line 3 Clean pilot see Cleaning and Maintenance page 11 or replace pilot...

Page 14: ...12 same 9 CIR Control Box see drawing same 10 Control Box Chassis CIR E CHA same 11 Power Adapter 120V NA not shown E POW 24VAC same 12 Burner Media not shown Crushed Glass 25 kg Lava Pebbles 18 L 13...

Page 15: ...R CIR E 24 BOX same 2 Dual Solenoid Valve C BUR E VAL BASO 278 w LP reg spring 3 3 8 x1 1 2 Nipple 4 3 8 Bulkhead Union 5 3 8 Street Elbow 6 Pilot Assembly PIL E 410 PIL E 410LP 7 Shrink fit Cord Grip...

Page 16: ...USTRATED PARTS LIST Wiring Diagram 1 2 3 4 5 10 6 7 11 8 9 MAIN GND VALVE PILOT GND BURNER GND 24V SENSE SPARK AC POWER ADAPTER INPUT AC 120V 60 Hz 8A OUTPUT 24 VAC 1 A CHASSIS GROUND PILOT PIL E 410...

Page 17: ...option replace or repair the defective components at no charge to the original owner Paloform will also pay for reasonable labor cost incurred in replacing or repairing such components Any products p...

Reviews: