PaloAlto Networks PA-7500 Quick Start Manual Download Page 3

PA-7500 QUICK START GUIDE (CONTINUED)

docs.paloaltonetworks.com

  |  © 2023 | Palo Alto Networks, Inc. | Part Number: 810-000370-00A

5

(Optional)

 If you are not able to connect to the management web interface, you can check the status of the firewall by connecting 

to the console port using the DB-9 to RJ-45 serial cable (provided) and terminal emulation software. The console connection 
provides access to firewall boot messages, maintenance mode, and the command line interface (CLI).

Page 3 of 3

Where To Go Next

To learn more about the firewall, refer to the PA-7500 Series Next-Gen Firewall Hardware Reference Guide: 

https://docs.paloaltonetworks.com/hardware

.

 

To learn how to configure Palo Alto Networks firewalls, go to the Technical Documentation portal: 

https://docs.paloaltonetworks.com

.

(Use the Getting Started information in the PAN-OS Administrator’s Guide for initial configuration tasks.)

Start here to Register and Set Up your firewall and access all resources and support tools:  

https://go.paloaltonetworks.com/CustomerLaunchPad

Connect in ZTP Mode

Unbox the firewall.

Connect the ZTP port (Ethernet port 1) on the firewall to the broadband connection. 

Power on the firewall.

Follow the instructions provided by your Panorama administrator to register your ZTP firewall. You will have to enter the serial number 
(12-digit number identified as S/N) and claim key (8-digit number). These numbers are on stickers attached to the back of the device.

Contact your Panorama administrator if you require further assistance.

Connect to the Management Interface 

 

Connect in Standard Mode

Connect the standard RJ-45 Ethernet cable from the RJ-45 port on your computer to the 
MGT port on the firewall. 

Ensure that you have access to a terminal emulator such as PuTTY. 

Power on the firewall. 

Access the firewall CLI using your terminal emulator. Watch for the following prompt: 

         

 Do you want to exit ZTP mode and configure your firewall in standard mode (yes/no)[no]?

 
          Enter “yes.” The system will then ask you to confirm. Enter “yes” again to boot the firewall in standard mode 
 

 
 
 

Stand by as the firewall boots up.

Change the IP address on your computer to an address in the 192.168.1.0/24 network, such as 192.168.1.2.

From a web browser, go to https://192.168.1.1.

When prompted, log in to the web interface using the default username and password (admin/admin). 

 

If you miss the above CLI prompt, you can also change your boot mode using the web interface. Go to the firewall login screen 
at any point before or during the startup process. A prompt will ask if you wish to continue booting in ZTP mode or if you 
would like to switch to standard mode. Select Standard Mode and the firewall will begin rebooting in standard mode. 

 

If installing AC power supplies

 — Connect the power supply to a 120VAC 15-amp circuit breaker or 240VAC 20-amp 

circuit breaker using the provided power cords. Repeat this step for each additional power supply, ensuring that each 
pair of power supplies is connected to its own circuit breaker. This ensures power redundancy and allows for planned 
electrical circuit maintenance. See 

Figure 13

.

 

If installing DC power supplies

 — Prepare the DC power cable (not included) by crimping the bare wire ends of the 

cables using lugs (not included) designed for your DC power source. Each cable dongle has one red wire and one black 
wire. Connect the red wire to the DC negative (-48VDC) terminal of your DC power source. Connect the black wire to the 
DC positive (RTN) terminal of your DC power source. Do this for each of the power supplies you are installing, ensuring 
that each pair of power supplies is connected to its own power circuit breaker. This ensures power redundancy and 
allows for planned electrical circuit maintenance. See 

Figure 14

. Connect the other ends of the DC cables to the front of 

the DC power supplies by pushing the plastic connector into the DC power supply until it clicks into place.

Figure 13

Figure 14

Crimp a 6-AWG wire to the provided grounding lug and connect the other end to your earth ground point.

Connect the two-post lug connector to the two-post ground studs on the appliance using the provided nuts and torque each nut to 50 in-lbs. Be 
careful not to strip the nuts and lug studs.

Connect the power supplies: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Install blanks into any unused power supply slots to help maintain chassis air flow. See 

Figure 15

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Turn on the power source and the firewall will power on.

Figure 15