SYMPTOM

Grinder won’t start

Excessive vibration

Grinder overheating

Fuses are being blown or 
circuit breakers are being tripped

Grinder will not operate in variable speed 
mode

POSSIBLE CAUSE(S)

1. Blown line fuse or tripped circuit breaker

2. Low line voltage

3. Material wedged between wheel 

and guard

4. Defective switch

5. Defective, blown capacitor

6. Defective circuit board

1. Improper mounting of grinder or 

accessories

2. Grinding wheel out of balance

3. Improper wheel mounting

1. Excess pressure required to grind material

2. Grinding on side of wheel

3. Motor not turning freely (without power)

1. Overloading due to binding

2. Defective plug

3. Defective cord

4. Defective switch

5. Faulty internal wiring

1. Defective variable speed switch

2. Defective sensor

3. Defective circuit board

CORRECTIVE ACTION

1. If fuse is blown, replace with fuse of 

proper size. If breaker tripped, reset it

2. Check power supply for voltage and 

correct as needed

3. Turn grinder off and remove material

4. Replace switch

5. Replace capacitor

6. Replace circuit board

1. Remount

2. Dress wheels or replace wheels

3. Remount wheels, but rotate one wheel

90º with respect to its previous position.
Other wheel should remain in its original
position

1. Dress wheel or replace wheel with one of

proper grit

2. Grind only on face of wheel

3. Clean around wheels and shaft and/or

replace bearings

1. Clean around wheels and shaft and/or

replace bearings

2. Replace plug

3. Replace cord

4. Replace switch

5. Contact your Palmgren distributor

1. Replace switch

2. Replace sensor

3. Replace circuit board

TROUBLESHOOTING

Palmgren Operating Manual & Parts List

82064A

Summary of Contents for 82064A

Page 1: ...operating manual parts list 82064A 6 Variable speed BENCH GRINDER Read carefully and follow all safety rules and operating instructions before first use of this product 37790 00 0713...

Page 2: ...locations Do not expose power tools to rain Work area should be properly lighted Proper electrical plug should be plugged directly into properly grounded three prong receptacle Extension cords should...

Page 3: ...flanges Mount the hose by sliding the flanges at each end over the exhaust ports on the left and right wheel guards Attach 2 shop vacuum hose to collector hose Be sure hose is mounted securely DANGER...

Page 4: ...All electrical connections must be performed by a qualified electrician Make sure tool is off and disconnected from power source while motor is mounted connected reconnected or anytime wiring is insp...

Page 5: ...Defective variable speed switch 2 Defective sensor 3 Defective circuit board CORRECTIVE ACTION 1 If fuse is blown replace with fuse of proper size If breaker tripped reset it 2 Check power supply for...

Page 6: ...stration for 6 Variable Speed Bench Grinder 1 4 5 7 8 10 27 47 21 23 3 2 48 13 12 23 14 19 15 40 37 26 29 25 39 18 11 45 30 34 26 42 36 35 30 33 31 32 26 49 15 12 18 17 28 10 19 12 13 44 41 23 51 52 5...

Page 7: ...4 20 x 3 8 Flange screw 16670 00 6 28 5 0 8 x 190mm Pan head screw 17995 00 2 29 Endshield 16617 02 1 30 Bearing 6202ZZ 01540 00 2 31 Motor fan 01608 00 1 32 Armature 1 33 Stator with housing 1 34 Gr...

Page 8: ...s Work stands 2 years Arbor presses 2 years Metal forming equipment 2 years Accessories 1 year The obligation of Palmgren is limited solely to the repair or replacement at our option at its factory or...

Reviews: