Pall WS10 Series Operating Instructions Manual Download Page 1

WS10

WS10 Series Water Sensor

service 

instructions

IMSIWS10

EN

W S 1 0   O p e r a t i n g   I n s t r u c t i o n s

ENGLISH

Summary of Contents for WS10 Series

Page 1: ...WS10 WS10 Series Water Sensor service instructions IMSIWS10 EN WS10 Operating Instructions ENGLISH ...

Page 2: ... Dimensions in mm inch 4 2 SPECIFICATION 4 3 INSTALLATION 5 3 1 Installation location 5 3 2 Installing the probe directly into the process 5 4 ELECTRICAL CONNECTIONS 5 5 MAINTENANCE 5 5 1 Sensor cleaning 5 5 2 Self diagnostic and error messages 5 6 ORDERING INFORMATION 5 7 DECLARATION OF CONFORMITY 6 8 TRADEMARKS AND INTELLECTUAL PROPERTY 7 9 WARRANTY LIMITATION OF LIABILITY 7 Contents ...

Page 3: ...e time of publication WARNINGS CAUTIONS AND NOTES Care must be taken in referring to this manual to ensure adherence with all warnings cautions and important notes These carry information related to the safety of personnel and the integrity and satisfactory operation of plant ENGLISH Safety instructions General Safety Instructions Excessive mechanical loads and incorrect usage should always be avo...

Page 4: ...t in oil WS10 is used for online monitoring of moisture in lubrication or insulation oil which is very important for the long term performance and preventive maintenance of plant and machinery Humidity measurement in oil is similar to the humidity measurement in the air the actual water content in oil can be indicated by the relative value RH RH actual water content expressed as a fraction of the ...

Page 5: ...e to circulate freely around the sensing element Mount the transmitter directly into the circulating system in a pipe that is always full of oil Reservoir mounting is not ideal unless the reservoir residence time is short 3 2 Installing the probe directly into the process When installing a probe directly into the process there should be a stop valve on both sides of the point of installation This ...

Page 6: ...ry use EMC requirements Test configuration operational conditions and performance criteria for transducers with integrated or remote signal conditioning ICES 003 ClassB This Interference Causing Equipment Standard sets out the technical requirements relative to the radiated and conducted radio noise emissions from digital apparatus FCC Part 15 ClassB Covers the regulations under which an intention...

Page 7: ...r repair alteration accident or negligence in use storage transportation or handling In no event will the Seller be liable for any damages incidental consequential or otherwise whether arising out of or in connection with the manufacture packaging delivery storage use misuse or non use of any of its products or any other cause whatsoever LIABILITY Pall does not accept warranty and liability claims...

Page 8: ...r area please go to www pall com contact Because of technological developments related to the products systems and or services described herein the data and procedures are subject to change without notice Please consult your Pall representative or visit www pall com to verify that this information remains valid Pall Industrial Manufacturing 25 Harbor Park Drive Port Washington NY 11050 1 516 484 3...

Reviews: