Pall UH319C Series Service Instructions Manual Download Page 2

UH319

UH319 Series

H I G H   P R E S S U R E   F I LT E R S

s e r v i c e  

i n s t r u c t i o n s

2

1

Specifications

Housing materials:

Head:

Ductile cast iron

Tube and Cover: 

Carbon steel 

Maximum operating pressure:

420 bar (6,100 psi)

Proof pressure:

750 bar (10,875 psi)

Typical burst pressure:

1,500 bar (21,750 psi)

Element burst pressure:

UE319 element 10 bard (150 psid) differential minimum

Operating temperature range:

-29°C to 120°C (-20°F to 250°F) with fluorocarbon seals for
petroleum based and specified synthetic fluids
60°C (140°F) maximum in HWCF, water-oil emulsion or 
water glycol

Bypass valve setting options:

4.5 ± 0.3 bard (65 ± 5 psid) cracking pressure

Seals:

Fluorocarbon
The actual operating conditions should be checked by the user
to ensure that the element, housing and all seals are
compatible with the fluid and application, and are within local
safety codes. Please contact Pall or an approved distributor if
further information is required.

2

Receipt of equipment

The filter housing, and any optional equipment, are packed
individually for assembly by the customer. Unpack carefully
and ensure optional items are not mislaid in packaging to 
be discarded.

3

General sources of information

3.1

For dimensions, operating parameters,
assembly/element part number, ordering information,
notes, performance data and specifications refer to
datasheet IMUH319EN.

3.2

This equipment has been assessed in accordance with
the guidelines laid down in the European Pressure
Directive 97/23/EC and has been classified within sound
engineering practice S.E.P. We hereby declare the
equipment meets the requirements of article 3, section
3, thus meeting the directive requirements. Under the
provisions of this directive the filter assembly is suitable
for use with group 2 fluids only.

3.3

Where under reasonably foreseeable conditions,
including external fires, the allowable limits could be
exceeded, suitable protective devices must be installed
by the customer within the connecting fluid system.

4

Installation of housing

4.1

The filter can be installed in any attitude, but for ease of
servicing, it is recommended that it be installed vertically
with the filter tube and cover pointing upwards
(UH319C) or with the filter tube and cover pointing
downwards (UH319H).

4.2

The minimum clearance required for element removal 
is as follows:
4.2.1

UH319C series (cover service): 205mm (8.1in) 
for length 8, 340mm (13.4in) for length 13, 
510mm (20in) for length 20 and 1020mm 
(40.2in) for length 40 housings.

4.2.2

UH319H series (head service): 138mm (5.5in) 
for all lengths.

4.2.3

The UH319 Housing is supplied without a filter
element.  For element installation and servicing
procedures, refer to Section 7.

4.3

Threaded differential pressure devices, when fitted, must
be torque tightened to 38 ft/lb or 54 Nm. All visual
indicators must be clearly visible.

NOTE: The UH319 head is supplied with two machined
differential pressure warning device ports, one fitted with a 
bleed plug, the other with a plastic shipping plug. If no differential
pressure warning device is ordered, the shipping plug must 
be removed and replaced with a 'B' type blanking plug 
(P/N HA9000A104Z) and torque tightened to 40 ft/lb /54 Nm.  
NOTE: Never place the port plug in this port without first
installing uniform size -014 O-ring in lower O-ring groove,
otherwise a small bypass flow will result, allowing contaminant
downstream of the filter element. 

4.4

Mount the filter assembly in position using four 
7/16-14 ('A' and 'E' ports) or M10 x 1.5 ('C' and 'G'
ports) bolts in the holes on the head mounting pads.
Torque bolts to 9-19 ft/lb or 12-26 Nm.

4.5

Use a check valve downstream of the filter if there is a
possibility of reverse flow.

4.6

Install the filter housing using additional piping/valving to
allow complete filter assembly bypass if filter maintenance
is required without system shutdown. This series is not
available in a duplex or service bypass configuration.

NOTE: Piping supports should be provided as close as is
practicable to the port connections in order to minimize
external loads. This filter assembly must not be electronically
isolated from the users earthing system. This filter assembly
must be earthed by connecting the users earthing system to
one of the inlet/outlet connections.

4.7

Connect lines or hoses to housing inlet and outlet ports.

CAUTION: 
Maximum surge flow should not exceed 1.3 times
normal flow.

WARNING:
USE FITTINGS OR ADAPTORS COMPATIBLE WITH
PORTS SUPPLIED AS SHOWN BY PART NUMBER ON
NAMEPLATE AND NOTED IN DATA SHEETS: USE OF
INCORRECT FITTINGS OR ADAPTORS CAN CAUSE
FILTER HOUSING OR MANIFOLD FAILURE
RESULTING IN LOSS OF PRESSURE AND POSSIBLE
SYSTEM FAILURE OR PERSONAL INJURY.

CAUTION:
Reverse flow through filter element will cause damage.

CAUTION:
Never operate the filter unless both warning device
ports are sealed. 

Summary of Contents for UH319C Series

Page 1: ...UH319 UH319 Series service instructions UK60898 IMSIUH319c EN UH319 Service Instructions ENGLISH ...

Page 2: ... is as follows 4 2 1 UH319C series cover service 205mm 8 1in for length 8 340mm 13 4in for length 13 510mm 20in for length 20 and 1020mm 40 2in for length 40 housings 4 2 2 UH319H series head service 138mm 5 5in for all lengths 4 2 3 The UH319 Housing is supplied without a filter element For element installation and servicing procedures refer to Section 7 4 3 Threaded differential pressure devices...

Page 3: ...abels 6 Differential pressure devices Reference should be made to product literature for dimensions operating parameters part numbering ordering information and specifications 6 1 Differential pressure devices actuate when the element needs changing or because of high fluid viscosity in cold start conditions 6 2 If visual indicator is fitted and actuates during cold start red button extends 5mm 3 ...

Page 4: ...its Servicing must be conducted using suitable tools that do not present a hazard Servicing must not be carried out when a potentially explosive atmosphere is present Refer to Service Parts List Section 9 for item numbers for applicable replacement element series Remove and replace element as follows 7 1 Turn off and depressurize the system 7 1 1 For UH319C series cover service Open vent plug 7 at...

Page 5: ...tered outside of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration accident or negligence in us...

Page 6: ...UH319 UH319 Series s e r v i c e instructions 6 2 4 8 6b 3 1 Figure 2 5 7 6 Not shown on this diagram Not shown on this diagram Inlet HIGH PRESSURE FILTERS ...

Page 7: ...ondeur AA 4 fori completamente filettati profondità AA 4 tapgaten met draad over volle diepte 4st fästhål Gänga Z Min gängdjup AA GG Q Flange Connection Details Flange Code Nominal Tube Size GG Q Z Thread AA E20 11 4 1 250 2 625 1 2 13 UNC 0 75 G20 11 4 31 8 mm 66 7 mm M12 x 1 75 19 mm E24 11 2 1 437 3 125 5 8 11 UNC 1 38 G24 11 2 36 5 mm 79 4 mm M16 x 2 00 35 mm E32 2 1 750 3 812 3 4 10 UNC 1 5 G...

Page 8: ... 2008 Printed in England IMSIUH319c Visit us on the web at www pall com Pall Corporation has offices and plants throughout the world in locations including Argentina Australia Austria Belgium Brazil Canada China France Germany India Indonesia Ireland Italy Japan Korea Malaysia Mexico the Netherlands New Zealand Norway Poland Puerto Rico Russia Singapore South Africa Spain Sweden Switzerland Taiwan...

Reviews: