UH210
UH210 Series
H I G H P R E S S U R E F I L T E R S
s e r v i c e
i n s t r u c t i o n s
2
1
Specifications
Housing materials:
Head and Cover:
Ductile cast iron
Tube:
Carbon Steel
Cage:
Stainless Steel
Maximum operating pressure:
414 bar (6,000 psi)
Proof pressure:
620 bar (9,000 psi)
Minimum burst pressure:
1500 bar (21,750 psi)
Element burst pressure:
UE210 element 10 bard (150 psid) differential minimum
Operating temperature range:
-29°C to 120°C (-20°F to 250°F) with fluorocarbon seals for
petroleum based and specified synthetic fluids
60°C (140°F) maximum in HWCF, water-oil emulsion or
water glycol
Bypass valve setting options:
4.5 ± 0.5 bard (65 ± 7 psid) cracking pressure
Non bypass
Seals:
Fluorocarbon
The actual operating conditions should be checked by the
user to ensure that the element, housing and all seals are
compatible with the fluid and application, and are within local
safety codes. Please contact Pall or an approved distributor if
further information is required.
2
Receipt of equipment
The filter housing, and any optional equipment, are packed
individually for assembly by the customer. Unpack carefully
and ensure optional items are not mislaid in packaging to
be discarded.
3
General sources of information
3.1 For dimensions, operating parameters, assembly/
element part number, ordering information, notes,
performance data and specifications refer to datasheet
M&EUH210EN.
3.2 This equipment has been assessed in accordance with
the guidelines laid down in the European Pressure
Directive 97/23/EC and has been classified within sound
engineering practice S.E.P. We hereby declare the
equipment meets the requirements of article 3, section
3, thus meeting the directive requirements. Under the
provisions of this directive the filter assembly is suitable
for use with group 2 fluids only.
3.3 Where under reasonably foreseeable conditions,
including external fires, the allowable limits could be
exceeded, suitable protective devices must be installed
by the customer within the connecting fluid system.
4
Installation of housing
4.1 The filter can be installed in any attitude, but for ease of
servicing, it is recommended that it be installed vertically
with the filter tube and cover pointing upwards (UH210) or
with the filter tube and cover pointing downwards (UH210).
4.2 The minimum clearance required for element removal is
as follows:
4.2.1
UH210 series (cover service): 147mm
(5.8in) for length 4, 248mm (9.8in) for length 8,
383mm (15.1in) for length 13 and 553mm
(21.8in) for length 20 housings.
4.2.2
UH210 series (head service): 81mm (3.2”)
for all lengths.
4.2.3
The UH210 Housing is supplied without a
filter element. For element installation
and servicing procedures, refer to Section 7.
4.3 Threaded differential pressure devices, when fitted,
must be torque tightened to 40 lb/ft or 54 Nm. All
visual indicators must be clearly visible
NOTE: The UH210 head is supplied with a machined differential
pressure warning device port, fitted with a plastic shipping plug.
If no differential pressure warning device is ordered, the shipping
plug must be removed and replaced with a ‘B’ type blanking
plug (HA9000A104Z) AND torque tightened to 40lb/ft /54Nm.
NOTE: Never place the port plug in this port without first
installing uniform size -014 O-ring in lower O-ring groove,
otherwise a small bypass flow will result, allowing contaminant
downstream of the filter element.
4.4 Mount the filter assembly in position using four
7/16”-14 (‘A’ and ‘E’ ports) or M10 x 1.5 (‘C’ and ‘G’
ports) bolts in the holes on the head mounting pads.
Torque bolts to 9-19 lb/ft or 12-26 Nm.
4.5 Use a check valve downstream of the filter if there is a
possibility of reverse flow.
4.6 Install the filter housing using additional piping/valving to
allow complete filter assembly bypass if filter maintenance
is required without system shutdown. This series is not
available in a duplex or service bypass configuration.
NOTE: Piping supports should be provided as close as is practicable
to the port connections in order to minimize external loads. This filter
assembly must not be electronically isolated from the users earthing
system. This filter assembly must be earthed by connecting the
users earthing system to one of the inlet/outlet connections.
4.7 Connect lines or hoses to housing inlet and outlet ports.
CAUTION:
Maximum surge flow should not exceed 1.3 times normal
flow.
WARNING:
USE FITTINGS OR ADAPTORS COMPATIBLE WITH
PORTS SUPPLIED AS SHOWN BY PART NUMBER
ON NAMEPLATE AND NOTED IN DATA SHEETS:
USE OF INCORRECT FITTINGS OR ADAPTORS CAN
CAUSE FILTER HOUSING OR MANIFOLD FAILURE
RESULTING IN LOSS OF PRESSURE AND POSSIBLE
SYSTEM FAILURE OR PERSONAL INJURY.
CAUTION:
Reverse flow through filter element will cause damage.
CAUTION:
Never operate the filter unless the warning device port is sealed.