Pall UH209 Series Service Instructions Manual Download Page 6

UH209

UH209 Series

H I G H   P R E S S U R E   F I LT E R S

s e r v i c e  

i n s t r u c t i o n s

6

2

4

5

3

Figure 2

Inlet

Summary of Contents for UH209 Series

Page 1: ...UH209 UH209 Series service instructions IMSIUH209 EN UH209 Service Instructions ENGLISH ...

Page 2: ...installation and servicing procedures refer to Section 7 4 3 Threaded differential pressure devices when fitted must be torque tightened to 38 ft lb or 54 Nm All visual indicators must be clearly visible NOTE The UH209 head is supplied with one machined differential pressure warning port fitted with a plastic shipping plug If no differential pressure warning device is to be installed the shipping ...

Page 3: ...tart conditions 6 2 If visual indicator is fitted and actuates during cold start red button extends 5mm 3 16 reset by depressing the button when the normal operating temperature is reached If indicator actuates after resetting replace element NOTE Option P visual indicator has thermal lockout and manual reset No signal below 0 C 32 F signal above 29 C 80 F 6 3 If the electrical switch actuates e g...

Page 4: ...ntained and operated at ratings specifications and design conditions will be free from defects in material and workmanship By way of explanation and not limitation the Seller does not warrant the service life of the filter element as this is beyond the Seller s control and depends upon the condition of the system into which the filter is installed 4 7 Filter element installation servicing During s...

Page 5: ...e liable for any product altered outside of the Seller s factory except by Seller or Seller s authorized distributor and then as to the latter only for products which have been assembled by the distributor in accordance with Seller s written instructions Nor shall Seller be liable for a product subjected to misuse abuse improper installation application operation maintenance or repair alteration a...

Page 6: ...UH209 UH209 Series HIGH PRESSURE FILTERS s e r v i c e instructions 6 2 4 5 3 Figure 2 1 Inlet ...

Page 7: ...UH209 UH209 Series HIGH PRESSURE FILTERS s e r v i c e instructions 7 ...

Page 8: ...2008 Printed in England IMSIUH209 Visit us on the web at www pall com Pall Corporation has offices and plants throughout the world in locations including Argentina Australia Austria Belgium Brazil Canada China France Germany India Indonesia Ireland Italy Japan Korea Malaysia Mexico the Netherlands New Zealand Norway Poland Puerto Rico Russia Singapore South Africa Spain Sweden Switzerland Taiwan T...

Reviews: