ELECTRICAL INSTALLATION
EXTEND HEAVY DUTY CABLE (Single Pole Application)
Note
: If power pack is to be wired Earth Return (Single Pole) check the specification of lead
extending from battery to chassis/body earth.
Always use battery cable and terminals supplied with the lift, current and capacity of the leads are
designed to match the power packs supplied.
Minimum Cable Spec.:
Model
Power pack
Voltage
Cable size
V500/V750
800W
12/24V
16mm
2
V750/V1000
1600W
12V
35mm
2
V750/V1000
2200W
24V
25mm
2
Note
: Use the existing clamp bolt as the connection (this is the positive terminal for negative earth
return). Do not connect battery until last operation.
1. Extend cable to the power pack starter solenoid terminal; choose a run where cable will
not be damaged. Ideal sites are inside the chassis main members or along the chassis
runner. Follow existing wiring looms where possible.
Note
: At no point should this cable be within 25mm of any brake line or hydraulic line. Clip the
cable to the chassis or body at a nominal pitch of 300mm. Care should be taken to prevent chafing
of any wiring against sharp edges and grommets must be used where wiring passes through any
frame members.
WIRING MUST NOT BE ATTACHED TO BRAKE OR HYDRAULIC LINES FOR SUPPORT.
2. When wiring earth return (
SINGLE POLE
), check specification of lead from battery to
chassis/body earth.
If lead capacity is less than shown below, fit lead of 2 x 25mm
2
300 amp capacity instead of, or as
well as the existing one.