ILUK 33/44/55/60
Owner’s Manual
Rev.1.5
31
8.1.2 ON-OFF Switch is On, But All Functions are Dead
Possible Malfunctions:
1. Short in hand held remote or its wiring.
Unplug hand controls.
2. Short in Control box wiring.
Remove Plug J-30 (Reference Electrical Schematic to
location Plug J-30).
3. After disconnecting plugs, reboot board by unplugging J-1 for 5 seconds and plug it back.
8.1.3 Warning Lights ON, after ON-OFF Switch is Turned OFF
1. B-15 Sensor is not working.
Make sure the wire strain relief is alwas parallel with the top of the platform.
8.1.4 Platform Tilts Down Before it Reaches The Ground
1. Adjust B-13 liftarm sensor.
2. B-13 is not working.
Unplug J41 (Gate operates without sensor but losses
auto tilt function).
If gate is still not working, take Truck/Trailer to a repair station