7.5.2 PRO 3
Room thermostat for right and left fan control (PRO 3)
It is possible to connect two room thermostats to the terminal board of the stove so that the right and left fans can
be switched on and off according to the temperature set on the thermostats.
To use this function, right and left fan ventilation must be set to ON.
The thermostat that controls the right fan must be connected to terminals 5 and 6 of the terminal board in place
of the bridge.
The thermostat that controls the left fan must be connected to terminals 3 and 4 of the terminal board in place of
the bridge.
7.6 Electrical connection
Simply connect the appliance to the electrical system using the supplied plug (
Fig. 41
).
The electrical connection (plug) must be easily accessible after appliance installation as well.
If the power supply cable is damaged it must
be replaced by the technical assistance service
or a qualified technician in order to prevent
any risk.
The system must be equipped with an earth
connection and a differential switch in compli-
ance with the laws in force.
The flue gas evacuation duct must be equipped
with its own earth connection.
B
B
C
C
TA
TA
A
A
Fig. 39
22.15 20.3 °C
1
2
3
4
5
6
T
1
6
22.15 20.3 °C
Fig. 40
Fig. 41