6.2.1 Coaxial pipe
A coaxial pipe can be used to expel the flue gases
and at the same time withdraw combustion air.
To achieve this:
• Connect a coaxial pipe
(A) given that the stove
is already factory configured for this type of in-
stallation (
It being understood that it is the technician’s
responsibility to properly size the chimney
flue based on the installation situation and the
product, it is nonetheless recommended not
to exceed a length of 7 metres with an 8/13 cm
coaxial pipe.
A
Fig. 14
6.2.2 Single wall pipe and air intake in room
In this case the combustion air will be taken from
the room.
To achieve this:
• Insert the aesthetic ring support
(A) (supplied
with and placed inside the combustion cham-
ber during transport).
• Connect the flue gas pipe
(B) (Fig. 15)
B
A
Fig. 15
Summary of Contents for MEGHAN