. 5.5.1
5.4.4 Air intakes with optional ventilation kit 680 m³/h.
,QDGGLWLRQWRWKHFRPEXVWLRQDLULQWDNH³&´¿JWKH
following air intakes must be provided for the fan:
X
Room air intake to heating circuit fan, located laterally
to the cladding (diameter 15 cm) with grille.
Y
Room air intake (connected as (
X
(-5.6-)), or
alternatively connected to an adjacent room (with the
H[FHSWLRQRIWKHEDWKURRPNLWFKHQEHGURRPGLDPHWHU
15 cm) with grille (-5.7-).
Depending on the solution adopted, during the dry test
installation it is advisable to mark the position of the air
LQWDNHVRQERWKWKHFODGGLQJDQGWKHH[WHUQDOZDOO
•
The fan air intakes can be provided with an
adjustable closure shutter, and must be equipped
with anti-insect screens.
•
,WLVLQGLVSHQVDEOHWRFOHDQ¿OWHUVRU¿QHPHVKJULOOHV
periodically because they may become clogged.
5.5 AIR
CIRCULATION
There are three possible solutions to hot air circulation:
1. NATURAL CIRCULATION (STANDARD)
(supplied with the machine)
2. NATURAL CIRCULATION WITH HOOD
(with the Natural ventilation with hood kit)
3. FORCED CIRCULATION WITH HOOD
With the Centrifugal fan with adjustment unit kit and
Ventilation with hood kit.