ITALIANO
ENGLISH
DEUTSCH
FRANÇAIS
ESPAÑOL
004779192 - 05/04/2023
19
ECOFIRE JACKIE IDRO
IDRO 26
Min
Max
Overall thermal power (output)
kW
4.6
26
Thermal power to water
kW
3.9
24.6
Yield
%
96.4
94
Flue gas temperature
°C
59.3
137
Flue gas flow rate
g/s
4.56
13.2
Hourly fuel consumption
kg/h
1
5.75
Emissions of CO (at 13% of O2)
mg/
Nm
3
276
94
Flue gas outlet
mm
Ø 80
Combustion air inlet
mm
Ø 60
Outside air intake
mm
Ø 100
Fuel
Wooden pellets
Flue draught
Pa
12 ± 2
Minimum draught for chimney sizing
Pa
0.0
Stove suitable for rooms no smaller than
m
3
40
Feeding tank capacity
kg
27
Weight
kg
223
No. of room fans
no.
1
Room fan flow rate
m
3
/h
100
Maximum operating pressure
bar
2.5 (200000 Pa)
Water content in the boiler
litres
42.3
Electrical data
JACKIE IDRO 26
Voltage
V
220-240
Frequency
Hz
50
Max power absorbed during operation
W
45
Power absorbed at electric ignition
W
360