18
Technical specs
Hot supply index
left, red color
Cold supply index
right, blue color
Limits of use recommended by UNI EN 817 for good functioning
Pressure
Min = 1 bar
Max = 5 bar
Temperature
Max = 65
o
Warning
It is of fundamental importance that the device is installed respecting the
input positions of the water supply, hot on the left and cold on the right.
It is necessary to execute a very careful flushing of the system to prevent
damage to both the faucet and the technological devices installed.
The supply pipes must be rinsed carefully before installing the mixer, so
that no chips, welding residues or other impurities remain inside the pipes.
A centralised filter would protect the system from impurities contained in
the water.
In order to guarantee a long product life it is better to install under-sink
taps with a filter, to be cleaned periodically.
Before starting up, unscrew the aerator and rinse very well.
In case of supply pressures over 5 bar, we recommend the installation of
a pressure reducer for the proper function of the equipment.
Installations performed differently than indicated do not allow the mixer to
operate properly.