ATTENTION

!

FORBIDDEN!

• 

Never use the unit to support other equipment.

• 

Never leave tools, spare parts, etc� inside the unit�

• 

Make sure that all inspection panels are closed properly�

• 

Do no expose the unit to inflammable gases.

ATTENTION

!

ONLY 

QUALIFIED 

PERSON

• 

In case of breakdown or failure: turn unit off, do not try to repair it on your own, call operator.

• 

If you are going to leave the heater switched off for a long time, first make sure that in no way this could cause 

harm to anyone in any way�

• 

The delivery must be made according to the following:

 

The package must be carefully secured in the loading space�

 

The package must be transferred in a closed space (always keep packing parts away environmental impacts)�

• 

The unit has a special safety packing for transport and delivery which must be kept in good conditions till the unit is positioned  

 

on the installation place�

• 

Make sure that the unit has all its parts, as specified in the order.

• 

Check if there are any damages and if the unit abbreviation is the same as the one of the ordered model�

• 

Every unit is factory tested before shipment, therefore, if there are damages, report them immediately to the carrier�

Transporting, unloading and moving is a process which must be made carefully to avoid any kind of damages. Try not to use the unit’s 

components as hand holds. When lifting, bear in mind that the centre of gravity of the unit may be off-centre.

 

CAUTION

!

DANGER

!

ATTENTION

!

THE USIGE OF 

MOVING EQUIPMENT

 

IS COMPULSORY 

 

ATTENTION

!

FORBIDDEN!

ATTENTION

!

ONLY 

QUALIFIED 

PERSON

The device is placed in cardboard box, one-way pallets are delivered�

Unpacking process:

•  remove the bands from packing of device, the carton box and the covering foil. Screw off the 4 pcs M8x45 fixing bolts on back 

side of pallet hereby the device can be removed from pallet�

• 

do not remove the protection caps from device and gas installing set until the gas attachment 

• 

investigate the device if it is not damaged during the transportation

• 

if it is damaged in that case notify the retailer from whom the device was bought!

There is an envelope inside the unit containing the Instructions for Installation and Servicing, User’s Guide use and Guarantee and ser

-

vices and the warranty documents�

The appliance operates based on direct heater principle, that means the heater air is blowed into the heated room directly for assuring of 

requested temperature. Besides HEATING (winter) mode the appliance can achieves the VENTILATION of room as well (summer mode).

Principle:

 The warm air blower appliance burns up the sucked mixture of combustion air and gas (S-,L-,Propan or natural gas), in this 

way making the heater air,which is blowed into the heated room (by direct blowing or through air duct) in order to ensure the keeping of 

temperature on requested value.

The heating and consumption values to be found as per appliance and gas types in  the 

enclosure 1.b.

The supply of  combustion air of appliance can be realized in two ways:

• 

directly from the heated place (A,C)

• 

from open air (CL), it can be used in case of such plants, which are working with dangers materials as follows: painting work-

shops and workshops,which are using explosive or corrosive materials etc…

The combustion products flow through the exchanger pipes towards the flue system while heat up it, parallel with this process the blower 

fan circulates the sucked inside or outside air through the heat exchanger assuring the needed warm air for heating� (the heater air is 

average 50°C) 

The air supply of blower fan can be solved in two ways:

• 

by direct sucking in from the heated place  (A, C, CL types),

• 

by sacking in from outside (CL type)�

The made warm air can be passed into the heated place in two ways:

• 

by direct blowing in through the leading lamellas (A, C types),

• 

by blowing in  and leading through air duct to the demanded places (in this case there are no lamellas on the device)�Such as 

the C and CL type of GTV�

The technical data of appliance can be found in the 

enclosure 1.

3.  

Transportation, unpacking, handling

4.

  

Operation principle

Summary of Contents for GTV Series

Page 1: ...TURAL GAS FIRED GTV TYPE WARM AIR BLOWERS User s manual GTV 68A GTV 78A GTV 87A GTV 97A GTV 107A GTV 116A Appliance types GTV 20A C CL GTV 27A C CL GTV 33A C CL GTV 40A C CL GTV 48A C CL GTV 58A C CL...

Page 2: ...9 Optional accessories 10 6 Appliance specification 10 Ventilation 10 Protective distances 11 7 Appliance operation 11 Start restart 11 Control and regulation of appliance 12 10 Maintance 13 Maintena...

Page 3: ...each your gas supplier call the Fire Department The GTV type warm air blower appliances have been developed and certified in compliance with MSZ EN 1020 standard and qualified for heating of industria...

Page 4: ...leave it to grow old Do not use seriously aged equipment any longer Fix the appliance on such stable surface which during operation despite warming of appliance preserves its stability If the applian...

Page 5: ...orma tions ATTENTION COMPULSORY EARTHING ATTENTION ONLY QUALIFIED PERSON CAUTION DANGER CAUTION ELECTRIC SUPPLY According to the installation project install the electric power lines Always make sure...

Page 6: ...attachment investigate the device if it is not damaged during the transportation if it is damaged in that case notify the retailer from whom the device was bought There is an envelope inside the unit...

Page 7: ...las or through the attached air duct to the demanded places 5 picture Axial fan type warm air blower 6 picture Centrifugal fan type with lamella execution Features suction in of heater air can be from...

Page 8: ...Possible regulation mode controlled by AHP 1 type thermostat Regulation possibilities Applicable regulatory options according to regulation ECO DESIGN EU2016 426 3 point modulation GTV 20 78 kW L N A...

Page 9: ...between the programme clock and warm air blower is solved by just one wire namely by control cable The automatic burner control located in the appliance receives and processes the transmitted control...

Page 10: ...he status of differential air pressure switch is changed during operation namely switches over from work switched on position to ba sic standstill position in that case the automatic electronic contro...

Page 11: ...e room temperature You have a chance daily and weekly programming with time switch Thermostat and appliance Appliance is under voltage with selector In this case the green lamp is lighting and you can...

Page 12: ...which disassembly of appliance is necessary supervision of nozzle pressure at the outlet of solenoid valve check of the condition of pressure regulator check of the protective ground check of the elec...

Page 13: ...al authorized representative or a qualified service department Gas change ATTENTION This action can only be realized by outhorized expert or service ATTENTION If the heater appliance is working than i...

Page 14: ...on A 0 9 0 9 1 77 1 77 1 9 1 9 Electrical performance W 0 21 0 21 0 41 0 41 0 44 0 44 Noise level dB A 53 53 55 55 55 57 Weight kg 64 86 95 IP protection of device IP21 Modell GTV 68A GTV 78A GTV 87A...

Page 15: ...5 8 3 5 9 2 6 9 2 6 Electrical performance kW 943 943 1150 1150 1380 1380 Noise level dB A 56 58 56 58 58 58 Weight C kg 70 93 121 Weight CL kg 75 98 126 IP protection of device IP21 Type Input Output...

Page 16: ...10 510 625 805 187 GTV 40A 610 510 625 805 187 GTV 48A 750 650 625 805 252 GTV 58A 750 650 625 805 252 Type A a b M e GTV 68A 810 700 840 970 238 GTV 78A 810 700 840 970 238 GTV 87A 960 850 840 970 31...

Page 17: ...CL GTV 33A C CL GTV 40A C CL GTV 48A C CL GTV 58A C CL Venting set type Maximal lenght of venting set 100 mm m B22 3 4 6 6 8 8 C12 3 4 6 6 8 8 C32 3 4 6 6 8 8 C52 3 4 6 6 8 8 Venting set type Maximal...

Page 18: ...2E3P 20 37 PL GTV 20A C CL GTV 58A C CL I2HS3P 25 28 30 50 HU GTV 68A GTV 116A I2H3P 25 28 30 50 HU I3P 50 NL The appliances were tested together with the flue system recommended by the manufacturer T...

Page 19: ...mission efficiency hs flow 94 21 Seasonal space heating energy efficiency hs h 72 7 Model GTV 20A C CL MOD Modulated Indirect gas fired forced convection air heater with axial fan B1 Warm air heater N...

Page 20: ...s flow 93 70 Seasonal space heating energy efficiency hs h 72 8 Model GTV 27A C CL MOD Modulated Indirect gas fired forced convection air heater with axial fan B1 Warm air heater No C2 Warm air heater...

Page 21: ...s flow 93 71 Seasonal space heating energy efficiency hs h 72 6 Model GTV 33A C CL MOD Modulated Indirect gas fired forced convection air heater with axial fan B1 Warm air heater No C2 Warm air heater...

Page 22: ...s flow 93 70 Seasonal space heating energy efficiency hs h 72 7 Model GTV 40A C CL MOD Modulated Indirect gas fired forced convection air heater with axial fan B1 Warm air heater No C2 Warm air heater...

Page 23: ...s flow 93 87 Seasonal space heating energy efficiency hs h 72 7 Model GTV 48A C CL MOD Modulated Indirect gas fired forced convection air heater with axial fan B1 Warm air heater No C2 Warm air heater...

Page 24: ...s flow 93 54 Seasonal space heating energy efficiency hs h 72 8 Model GTV 58A C CL MOD Modulated Indirect gas fired forced convection air heater with axial fan B1 Warm air heater No C2 Warm air heater...

Page 25: ...s flow 93 70 Seasonal space heating energy efficiency hs h 73 5 Model GTV 68A MOD Modulated Indirect gas fired forced convection air heater with axial fan B1 Warm air heater No C2 Warm air heater No C...

Page 26: ...s flow 92 64 Seasonal space heating energy efficiency hs h 72 4 Model GTV 78A MOD Modulated Indirect gas fired forced convection air heater with axial fan B1 Warm air heater No C2 Warm air heater No C...

Page 27: ...rized retailer or service station The regular maintenance is the owner s responsibility The manufacturer does not assume the responsibility in case of accidentally happened or directly caused mistake...

Page 28: ...PAKOLE TRADE Ipari s Kereskedelmi Kft H 8000 Sz kesfeh rv r B rg ndi t 8 10 http www pakole com E mail mail pakole hu Tel 36 22 316 484 Fax 36 22 316 074 www pakole com...

Reviews: