background image

ACR 

air curtains 

Contents

Contents

1.  GENERAL AND SAFETY PRINCIPLES

 ..................................................................................................................................3

2.  PURPOSE OF THE DEVICE

 .....................................................................................................................................................4

3.  BASIC TECHNICAL PARAMETERS

 ........................................................................................................................................4

4.  HEAT OUTPUT RANGES

 ..........................................................................................................................................................5

ACR 100-150-200 W Air curtains with water heater ...............................................................................................................5
ACR 100-150-200 E Air curtains with electric heater .............................................................................................................5

5.  INSTALLATION

 ..........................................................................................................................................................................6

Installation using brackets for vertical mounting ....................................................................................................................8
Connection of heating medium ..............................................................................................................................................9
Connecting the power supply and control system of the curtain ............................................................................................9

6.  CONTROL PANEL

 ...................................................................................................................................................................10

7.  ACR DOOR SWITCH

 ...............................................................................................................................................................10

8.  DIAGRAMS OF ELECTRICAL CONNECTIONS

 ...................................................................................................................11

Diagram of connecting one ACR 100-150-200 W (water heater) and C  .............................................................................11
(without heater) to the COMFORT panel .............................................................................................................................11
Diagram of connecting two ACR 100-150-200 W (water heater) and C (without heater) to one COMFORT panel  ...........11
Diagram of connection of one ACR 100-150-200 E curtain (electric heater) to the COMFORT panel ................................12
Diagram of connection of two ACR 100-150-200 E curtain (electric heater) to one COMFORT panel ................................12
Diagram of connection of one ACR 100-150-200 E curtain (electric heater) to the COMFORT panel ................................13
Connection diagram of ACR 100-150-200 W and C with BMS module ...............................................................................14
Diagram of connection of ACR 100-150-200 E curtain with BMS module ...........................................................................15

9.  DIMENSIONS OF THE ACR 100-150-200 W, E, C CURTAINS

 ............................................................................................16

10.  OPERATION AND MAINTENANCE

 .....................................................................................................................................17

11.  TROUBLESHOOTING AND TECHNICAL PROBLEMS

 .....................................................................................................17

Summary of Contents for ACR 100C

Page 1: ...EN Operation and Maintenance Documentation www pakole com 008_039_011_190902__V001_en Type ACR 100W ACR 100E ACR 100C ACR 150W ACR 150E ACR 150C ACR 200W ACR 200E ACR 200C AIR CURTAINS...

Page 2: ...100 150 200 W water heater and C 11 without heater to the COMFORT panel 11 Diagram of connecting two ACR 100 150 200 W water heater and C without heater to one COMFORT panel 11 Diagram of connection o...

Page 3: ...air curtain is connected directly to the cable please make sure there is a splitter protecting against any undesired discon necting Pay special attention while transporting the device not to damage t...

Page 4: ...ting cold air from entering the heated space In summer the curtains may be used as cooling devices preventing the entry of hot air and pollutants from outside The ACR air curtains are designed to prot...

Page 5: ...pirals Large heat exchange surface surface of contact of the heat exchanger with heated air Fully automatic heat control depending on air flow Complete elimination of the risk of system overheating du...

Page 6: ...ol panel With larger door openings it is possible to mount more curtains of the same type one by one to create an uninterrupted air flow The curtain is permanently mounted in either a horizontal or ve...

Page 7: ...the wall in a horizontal position using 2 mounting brackets to the horizontal system In the brackets there are 9mm holes for M8 screws In the EPP housing drill holes 12 13mm in front of existing hole...

Page 8: ...g drill holes 12 13mm in front of existing holes in the steel in take grille The exact location is indicated by special tags on the EPP housing and the figure below Then insert the spacer sleeves into...

Page 9: ...er use a vent which is located on the exchanger collector on the engine side ATTENTION It is necessary to ensure that the unit is properly leveled When it is mounted in a position other than vertical...

Page 10: ...L not supported function in this settings the device does not work To install the control panel unscrew the screw remove the front cover and panel board fix the panel to the wall and replace the panel...

Page 11: ...not include power cord or main switch Diagram of connecting one ACR 100 150 200 W water heater and C without heater to the COMFORT panel Power supply 230V 50Hz Security system B4 Cross section of pow...

Page 12: ...E B25 Control Panel COMFORT 3 speed fan control with thermostat OMY 5x 1 0mm In the MASTER curtain between the L1 NC terminal replace the factory made fuse C 3 15 with C 6 3 400V 50Hz power supply wir...

Page 13: ...circuit between terminal 3 on Comfort Panel and Terminal 2 in the ACR curtain The on off switch itself should be installed in a place suitable for the curtain user Warning The Comfort Panel thermostat...

Page 14: ...ated PP OPERATION Digital signal 1 potential free contact closed information about the operation of the curtain reed relay on door opened Digital signal 0 potential free contact opened Reed relay off...

Page 15: ...he COMFORT panel in ON position READY FOR OPERATION 1 signal activated PP OPERATION Digital signal 1 potential free contact closed information about the operation of the curtain reed relay on door ope...

Page 16: ...16 ACR air curtains Operation and Maintenance Documentation 9 DIMENSIONS OF THE ACR 100 150 200 W E C CURTAINS...

Page 17: ...at input disconnected Only suitably qualified staff well acquainted with the safety regulations concerning handling with an electrical device must be employed when the device is being installed starte...

Page 18: ...authorized retailer or service station The regular maintenance is the owner s responsibility The manufacturer does not assume the responsibility in case of accidentally happened or directly caused mi...

Page 19: ......

Page 20: ...PAKOLE TRADE Kft H 8000 Sz kesfeh rv r B rg ndi t 8 10 www https www pakole com E mail mail pakole hu Tel 36 22 316 484 Fax 36 22 316 074 www pakole com...

Reviews: