6
HLU-231 List 3D
Using the SEL and MODE Front Panel Buttons
To provision the HLU-231 List 3D through the SEL and MODE front-panel
buttons:
1
Press the MODE button for approximately one second. The message
displayed on the front panel alternates between the first system parameter
and its current setting.
2
Press the SEL button to step the display through all possible settings (one
at a time) of the parameter being displayed.
3
Press the MODE button to select the desired parameter and move to the
next parameter. After you have configured the last parameter, the dis-
play prompts you to confirm the settings.
4
Do one of the following:
•
Press the SEL button to install the settings.
•
Press the MODE button to bypass the settings.
If neither button is pressed in 30 seconds, the settings are bypassed.
Default Settings
To return the system options back to the original factory default settings:
1
Press the SEL button until the
DFLT NO
message appears.
2
Press the SEL button again and
DFLT YES
displays indicating the fac-
tory default values are now in effect.
To terminate the DFLT mode without setting the factory default values,
press the MODE button or do nothing for 30 seconds.