150-388-151-01, Revision 01
Provisioning
HLU-388 List 5A
September 15, 1999
23
describes the System Settings options and lists the corresponding front-panel display codes. Factory
default parameters appear in boldface type.
Table 9.
HLU-388 List 5A System Settings
System Settings
Screen Options
Front-panel
Display
Code
Parameter
Description
Equalization
0
Sets the Equalizer to DSX-1 for 0 to 133 feet.
133
Sets the Equalizer to DSX-1 for 133 to 266 feet.
266
Sets the Equalizer to DSX-1 for 266 to 399 feet.
399
Sets the Equalizer to DSX-1 for 399 to 533 feet.
533
Sets the Equalizer to DSX-1 for 533 to 655 feet.
SmartJack Loopback LBPK
DIS
Configures the HiGain system to ignore all inband SmartJack loopback
commands.
ENA
Enables the HiGain system to recognize all inband SmartJack loopback
commands.
Special Loopback
SPLB
GNLB
Configures the HiGain system to respond to the generic inband loopback
codes.
A1LB and
A2LB
Configures the HiGain system to respond to the inband loopback codes of the
Teltrend addressable repeater.
A3LB
Configures the HiGain system to respond to the inband loopback codes of the
Wescom addressable repeater.
A4LB
Configures the HiGain system to respond to the inband loopback codes of the
Wescom Mod 1 addressable repeater.
A5LB
Configures the HiGain system to respond to the inband loopback codes of the
Teltrend Mod 1 addressable repeater.
Power
PWRF
DIS
Disables power to the HDSL pair.
(See
.)
LOW
Keeps the HDSL line voltage at -140 Vdc maximum for all applications.
AUTO
Allows the HDSL line voltage to automatically switch between -140 Vdc
maximum for non-doubler applications and ±112 Vdc for doubler
applications.
HIGH
Forces the HDSL line voltage to ±112 Vdc for all applications.
ZBTSI
ZBTS
ON
Tells the HiGain system that the ESF frame is operating in its Zero-Byte
Timeslot Interchange (ZBTSI) mode.
OFF
Tells the HiGain system that the ESF frame is operating in its normal
non-ZBTSI mode.
BER Alarm
Threshold
BERT
1E-6
Alarm activates when BER threshold exceeds 10
-6
.
(See
.
1E-7
Alarm activates when BER threshold exceeds 10
-7
.
NONE
Prevents generation of a system alarm due to excessive BER.
Loopback Timeout
LBTO
NONE
Disables automatic time-out cancellation of all loopbacks.
20
Sets automatic cancellation of all loopbacks to 20 minutes after initiation.
60
Sets automatic cancellation of all loopbacks to 60 minutes after initiation.
120
Sets automatic cancellation of all loopbacks to 120 minutes after initiation.