Provisioning
150-231-185-05, Revision 05
16
September 13, 1999
HLU-231 List 8E
Span Status Screen without Doublers
Figure 5.
Span Status Screen: No Doubler
Span Status Screen for Doubler Applications
If doublers have been added, status is also reported for these. Span Status can have up to five screens, depending
on the number of HDUs.
Figure 6.
Span Status Screen: Four Doublers (Span 5)
SPAN STATUS
TIME: 00:27:25
DATE: 09/15/99 CIRCUIT ID#:
ALARMS: NONE
LOOPBACK: OFF
POWER LEVEL: LOW
HLU HRU
HDSL-1 HDSL-2 HDSL-1 HDSL-2
cur/min/max cur/min/max cur/min/max cur/min/max
MARGIN: 21/20/22 23/22/24 21/19/22 22/21/24 dB
PULSE ATTN: 00 00 00 00 dB
INS LOSS: 00 00 00 00 dB
24 HOUR ES: 00004 00003 00006 00007 seconds
24 HOUR UAS: 00014 00013 00000 00001 seconds
DS1 STATUS
HLU HRU
24 HOUR ES Count: 00001 00002
24 HOUR UAS Count: 00000 00002
Frame type: SF SF
Code type: AMI AMI
AUTOUPDATE OFF
(E)xit (C)lear (A)uto(U)pdate
SPAN 5 STATUS
TIME: 12:06:04
DATE: 09/15/99
ALARMS: NONE
LOOPBACK: OFF
POWER LEVEL: HIGH
HDU4 HRU
HDSL-1 HDSL-2 HDSL-1 HDSL-2
cur/min/max cur/min/max cur/min/max cur/min/max
MARGIN: 23/23/23 23/21/23 24/20/25 24/21/24 dB
PULSE ATTN: 07 07 07 07 dB
INS LOSS: 08 08 08 08 dB
24 HOUR ES: 00010 00008 00001 00002 seconds
24 HOUR UAS: 00021 00020 00004 00002 seconds
DS1 STATUS
HLU HRU
24 HOUR ES Count:
00000 00017
24 HOUR UAS Count: 00000 00012
Frame type: ESF ESF
Code type: AMI AMI
AUTOUPDATE OFF
(E)xit (C)lear (A)uto(U)pdate (S)pan(1)(2)(3)(4)(5)
Circuit ID#: