Front Panel
150-231-184-05, Revision 05
6
October 25, 1999
HLU-231 List 8D
lists the front panel display messages. The four-character displays report the code of an alarm, loopback
or diagnostic message, in some cases followed by a second four-character message that modifies the first message
with a value or current configuration setting.
Table 2.
Front Panel Display Messages
Message
Full Name
Description
ALARM MESSAGES
ACO
Alarm CutOff
A system alarm has occurred and has been retired to an ACO
condition by pressing the SEL button on the HLU front panel.
ALRM
Alarm Condition
A system alarm condition is in effect.
BER
Bit Error Rate
A system BER alarm is in effect.
LLOS
Local Loss of Signal
Indicates that no signal is detected at the DSX-1 input to the HLU.
LOSW
Loss of Sync Word
Indicates that one of the HDSL loops has lost its synchronization.
The Fast LOSW feature is enabled when the Bipolar Violation
Transparency (BPVT) option is enabled (see
MAL1 or MAL2
Margin Alarm Loop 1 or Loop 2
The margin on HDSL Loop 1 (or 2) has dropped below the threshold
(1 to 15 dB) as set by the operator.
RLOS
Remote Loss of Signal
Indicates that no signal is detected at the DS1 input to the HRU.
LOOPBACK MESSAGES
CDU
n
?
Customer Doubler
n
Loopback
Query to initiate loopback at doubler
n
to CI, where
n
is the number
of the doubler.
CLOC
Customer Local Loopback
Signal from Customer is looped back to the customer at the HRU.
CREM
Customer Remote Loopback
Signal from customer is looped back to the customer at HLU-231.
NDU
n
?
Network Doubler
n
Loopback
Query to initiate loopback at doubler
n
to network, where
n
is the
number of the doubler.
NLOC
Network Local Loopback
DSX-1 signal is looped back to DSX-1 at HLU.
NREM
Network Remote Loopback
DSX-1 signal is looped back to DSX-1 at the HRU.
SMJK
Remote SmartJack Loopback
Signal from DSX-1 is looped back at the HRU by the HRU SmartJack
module.