Provisioning
150-231-184-05, Revision 05
22
October 25, 1999
HLU-231 List 8D
RLOS Alarm
RDA
ENA
Enables a remote DS1 LOS condition at the input to the HRU to generate an
LOS alarm. AIS or LOS (depending on ALMP) is sent towards the network.
DIS
Prevents a remote DS1 LOS condition at the input to the HRU from causing
an LOS alarm. The front panel Status LED still flashes red and the ALRM RLOS
message is displayed, but the alarm relay contacts do not close and LOS (not
AIS) is sent towards the network from the HLU.
Alarm Pattern
ALMP
AIS
Enables HiGain to output an AIS payload at its DS1 ports for LOSW, T1 LOS
and Margin alarms.
LOS
Enables HiGain to output an LOS condition at its DS1 ports for LOSW, T1 LOS
and Margin alarms.
Remote Provisioning RTPV
ENA
Enables provisioning at the remote end (when remotely logged in).
DIS
Disables remote provisioning.
Bipolar Violation
Transparency
(See
below.)
BPVT
ENA
Enables BPVs and HDSL CRC errors at the DS1 input to be converted into DS1
BPVs at the distant end’s DS1output. This makes HiGain transparent to BPVs.
DIS
Inhibits reporting of BPVs and CRC errors at the DS1 input and disables the
Fast LOSW reporting function.
(a) Can also be configured using the MODE and SEL buttons on the HLU front panel.
Table 8.
HLU-231 List 8D System Settings (Cont.)
System Settings
Screen Options
Code
Parameter
Description