950-734-100-01, Revision 01
Conventions Used in This DocumentAdministration
PLL-734 List 1
December 18, 1998
27
HDSL Alarm Thresholds Screen
Provides a means to provision the threshold crossing values for the15 minute and 24-hour ES and UAS counts and
low margin dB for both A and B RTs.
Table 9
lists the fields of the HDSL Alarm Thresholds and the default
factory values.
1
Select CONFIG from the menu bar and press
to display the submenu.
2
Scroll to the HDSL Alarm Thrshlds line and press
to view the screen.
3
With the
desired
field highlighted, press
to toggle to the correct value for that field, then press
to move to the next option. Continue until you have made all desired changes
4
Use a directional key to move to the
Accept HDSL Alarm Thresholds Changes
button, press
to accept the changes or press
to return to the Main Menu with the values unchanged.
5
Press
to move up a menu level, or
+
to return to the PAU/PMU Main menu.
Table 9.
HDSL Alarm Threshold Fields
Thresholds
Description
Defaults
MAR
Value at which alarm is set active if margin drops equal to or less than this threshold.
Possible HDSL low margin threshold values include any values from 0 through 15.
6
ES-15 MIN
Value for the HDSL 15 minute interval ES alarm. Possible threshold values include any
number from 0 to 900.
17
ES -24 HR
Value for the HDSL 24 hour interval ES alarm. Possible threshold values include any number
from 0 to 86400.
170
UAS-15 MIN
Threshold value for the HDSL 15 minute interval UAS alarm. Possible threshold values
include any number from 0 to 900.
240
UAS-24 HR
Threshold value for the HDSL 24 hour interval UAS alarm. Possible values include any
number from 0 to 86400.
170