PairGain PG-Flex FSU-796 Quick Reference Manual Download Page 2

1

Press the LED Test switch on the FSU-796 List 5 front panel and verify that all Tip and Ring LEDs 
(T1-T8 and R1-R8) and power supply LEDs (-170 Vdc, 200 Vac, -30 Vdc, -52 Vdc, and ±5 Vdc)
are on. 

If no LEDs light, replace the 9V battery.

If no LEDs light after replacing the 9V battery, replace the FSU-796 List 5 Streaker card.

If any one of the LEDs do not light, replace the FSU-796 List 5 Streaker card.

1

Slide the FSU-796 List 5 into the RT enclosure channel unit slot to be tested until the retaining latch on the 
front panel locks into position. (Refer to Figure 1 for the channel unit locations.)

2

Proceed to "Verifying the Channel Unit Slot Wiring."

Use the following procedure to verify the wiring from each channel unit slot in an FRE-765 RT enclosure to the 
termination point.

1

At the cable termination point, connect a jumper lead from frame ground to the appropriate Tip or Ring 
subscriber termination and verify that the corresponding Tip or Ring LED on the FSU-796 List 5 is on. 

If the correct Tip or Ring LED lights, proceed to the next subscriber termination.

If the Tip or Ring LED under test does not light, or the wrong LED lights, check the wiring to the RT 
enclosure.

2

Repeat the previous step for each channel card Tip and Ring subscriber termination.

3

Proceed to "Testing the Line Unit Power Supply Voltages."

Verify that a 9V battery is installed on the FSU-796 List 5 Streaker card before starting this 
procedure.

An RT line unit is not required when testing the channel unit slot wiring.

Refer to the appropriate FRE-765 RT enclosure technical practice for channel unit 
subscriber terminations, and wire color or connector pin locations for the specific 
FRE-765 RT enclosure to be tested.

Before You Install the FSU-796 List 5

Installing and Testing the FSU-796 List 5

Verifying the Channel Unit Slot Wiring

Use the following procedure to verify that the line unit power supply voltages are present at each of the channel 
unit slots.

1

Slide the FSU-796 List 5 into the RT enclosure channel unit slot to be tested until the retaining latch on the 
front panel locks into position. (Refer to Figure 1 for the channel unit locations.)

2

Verify that the -170 Vdc, 200 Vac, -30 Vdc, -52 Vdc, and ±5 Vdc LEDs are on.

If any of the power supply LEDs do not light, replace the line unit.

If none of the power supply LEDs light, check that power is applied.

3

Repeat steps 1 and 2 for each channel unit slot.

.

Figure 1.  Channel Unit Slots CU1 - CU4

(FRE-765 List 4D and 4E Shown)

An RT line unit must be installed and operating (with power applied) to supply the FSU-796 
List 5 with the power supply voltages (-170 Vdc, 200 Vac, -30 Vdc, -52 Vdc, and ±5 Vdc) 
required for this test.

Testing the Line Unit Power Supply Voltages

9

10

8

7

6

5

4

3

2

1