Section 363-746-100
Revision 01
Page 3
Figure 2. Typical PG-Flex Configuration.
TABLE 1. PG-FLEX DISTANCES
Loop Length
Wire Gauge
16/32 Channel System
Resistance
26 AWG
(0.4 mm)
08.1 kft
(2.5 km)
686
W
24 AWG
(0.5 mm)
10.7 kft
(3.3 km)
569
W
22 AWG
(0.6 mm)
13.7 kft
(4.2 km)
457
W
19 AWG
(0.9 mm)
19.4 kft
(5.9 km)
322
W
pair) will be connected to either the corresponding COT
subscriber line or to the test access bus.
2.08
The test connection will be dropped when -116V
is applied to the subscriber’s COT tip for 1.5
seconds, then removing the -116 V.
2.09
Test access may also be activated through the
RS-232 Maintenance Port located on the front of
the COT and RT Line Units, using an ASCII terminal.
3. SPECIFICATIONS
RT Power Supply Input Voltage
+130 Vdc to +65 Vdc (Line 1)
-130 Vdc to 0 Vdc (Line 2)
Input Power (typical)
Less than 30 Watts
Operating Temperature & Humidity
-40° to +65° Celsius, 5% to 95%
(non-condensing)
Operating Elevation
200 feet (60 m) below sea level to 13,000
feet (4,000 m) above sea level.
Dimensions
Height:
12.00” (30.5 cm)
Width:
2.25”
(5.7 cm)
Depth:
4.50” (11.4 cm)
Weight
1.4 lb. (0.6 kg)