Loopback Operation
150-388-125-01, Revision 01
46
September 15, 1998
HLU-388 List 2E
Information specific to HiGain doublers is shown in bold in
.
Table 14.
Addressable 3 and 4 (A3LB and A4LB) Repeater Loopback Commands
Position
Name
Code
*
*
The left-most bit arrives first in all sequences. The detection algorithm functions reliably with a random
10
-3
Bit Error Ratio (BER) on the facility. The entire arming and loopback sequence can be initiated at the
remote HRU location.
HLU-388 LU FROM NI
NLOC
1111(F)
†
1111(F)0001(1)1110(E)
† This is the HEX number for the 4-bit group.
HLU-388 LU from CI
CREM
0011(3)1111(F)0001(1)1110(E)
HDU DOUBLER 1 FROM NI
NDU1
1111(F)1111(F)0000(0)1000(4)
HDU DOUBLER 1 FROM CI
CDU1
0011(3)1111(F)0000(0)0100(4)
HDU DOUBLER 2 FROM NI
NDU2
1111(F)1111(F)0000(0)0110(6)
HDU DOUBLER 2 FROM CI
CDU2
0011(3)1111(F)0000(0)0110(6)
HRU LU FROM NI
NREM
1111(F)1111(F)0000(0)0010(2)
HRU LU FROM CI
CLOC
0011(3)1111(F)0000(0)0010(2)
HRU LU FROM NI
SMJK
11000 11000 11000 ...
HRU LU FROM NI
SMJK
100000 100000 100000 ...
HRU LU FROM NI (ESF-DL)
SMJK
1111(F)1111(F)0100(4)1000(8)
HLU and HRU LD FROM NI OR CI
Loopdown
11100 11100 11100 ...
HLU and HRU LD FROM NI OR CI
Loopdown
100 100 100 ...
HLU and HRU LD FROM NI OR CI (ESF-DL)
Loopdown
1111(F)1111(F)0010(2)0100(4)