![PairGain HiGain Line Unit HLU-388 Manual Download Page 33](http://html2.mh-extra.com/html/pairgain/higain-line-unit-hlu-388/higain-line-unit-hlu-388_manual_3274143033.webp)
150-388-125-01, Revision 01
Maintenance
HLU-388 List 2E
September 15, 1998
23
S
YSTEM
S
ETTINGS
M
ENU
O
PTIONS
describes the System Settings menu options and their counterpart codes for the front panel display.
Table 9.
HLU-388 System Settings Menu Options
System Settings
Menu Options
Front Panel
Display
Code
Selection
Description
Equalization
EQL
0*
Sets the Equalizer to DSX-1 for 0 to 132 feet.
133
Sets the Equalizer to DSX-1 for 133 to 265 feet.
266
Sets the Equalizer to DSX-1 for 266 to 398 feet.
399
Sets the Equalizer to DSX-1 for 399 to 532 feet.
533
Sets the Equalizer to DSX-1 for 533 to 655 feet.
SmartJack Loopback LBPK
DIS
Configures the HiGain system to ignore all in-band SmartJack loopback
commands.
ENA*
Enables the HiGain system to recognize all in-band SmartJack loopback
commands.
Special Loopback
SPLB
GNLB*
Configures the HiGain system to respond to the generic (3/4 in 7) in-band
loopback codes.
A1LB and
A2LB
Configures the HiGain system to respond to the in-band loopback codes of the
Teltrend addressable repeater.
A3LB
Configures the HiGain system to respond to the in-band loopback codes of the
Wescom addressable repeater.
A4LB
Configures the HiGain system to respond to the in-band loopback codes of the
Wescom Mod 1 addressable repeater.
A5LB
Configures the HiGain system to respond to the in-band loopback codes of the
Teltrend Mod 1 addressable repeater.
Power
PWRF
DIS
Disables powering to the HRU and Doubler.
ENA*
Enables powering to the HRU and Doubler.
ZBTSI
ZBTS
ON
Tells the HiGain system that the ESF frame is operating in its Zero-Byte Time
Slot Interchange (ZBTSI) mode.
OFF*
Tells the HiGain system that the ESF frame is operating in its normal
non-ZBTSI mode.