![PairGain HiGain Line Unit HLU-388 Manual Download Page 27](http://html2.mh-extra.com/html/pairgain/higain-line-unit-hlu-388/higain-line-unit-hlu-388_manual_3274143027.webp)
150-388-125-01, Revision 01
Maintenance
HLU-388 List 2E
September 15, 1998
17
Span Status Fields, Alarms, and Loopbacks
lists the Span Status fields and descriptions.
lists all possible alarms and their
descriptions, and all possible loopbacks and their descriptions.
Table 7.
Span Status Fields and Descriptions
Field
Description
Time
Time of day when Span Status was checked.
Date
Date when Span Status was checked.
Circuit ID
Shows the user-defined circuit ID.
Alarms
Presence or absence of alarm conditions.
Loopback
Indicates Off condition or identifies specific active loopback.
Margin
Indicates the excess signal-to-noise ratio, at either the HLU or HRU, relative to a 10
-7
Bit Error Rate.
First value is current margin, second value is minimum margin since last cleared, and third value
is maximum value. NA means "Not Available." Minimum and maximum margin are cleared and
updated every time the Span Status screen is cleared and every day when the system clock passes
through at 12 p.m. midnight.
Pulse Attenuation (ATTN)
Indicates the attenuation of the 2B1Q pulse from the distant end. The value is related to the 196 kHz
loss of the cable pair. The pulse attenuation is a more direct indication of the loop attenuation to
the 2B1Q signal than is the 196 kHz loss. The normal HiGain ATTN operation range is from 0 to
28 dB.
PPM Offset
Indicates the relative offset of the crystal oscillator in the HLU from the HRU or HDU crystal
oscillator. Any value between -100 and +100 is adequate.
24-Hour ES
The number of one second intervals that contained at least one CRC error. This value is a running
total of the last 24 Hours.
24-Hour UAS
The number of seconds the HDSL loop was out of sync.
24-Hour BPV Seconds
The number of seconds in which at least one bipolar violation was detected on the DS1 input over
a 24-hour period.
24-Hour UAS Count
The number of seconds during which the DS1 input signal was absent (125 or more consecutive
zeros) over a 24-hour period.
Frame type
Type of DS1 framing used on the input stream (SF or ESF).
Code type
Type of DS1 line coding used (AMI, B8ZS, AMI: ZBTSI or B8ZS: ZBTSI). The latter two conditions
indicate the code type that is being received when HiGain is set to its ZBTS1 mode. In either the
AMI or B8ZS DS1 code mode, it displays the selected code as opposed to the code type that is
actually being received.