350-819-200-01, Revision 01
System Configuration
HLU-819 List 1
November 12, 1999
19
System Setting
Description
Remote Power
Feed Loop
No selection available.
BOTH
BOTH is displayed in UNSTRUCT (unframed), STRUCT (framed), and
TSP application modes. The LTU (HLU-819) uses Loop 1 and Loop 2
to supply power to the NTU.
LOOP1
LOOP1 displays in SINGLE application mode when POWER is selected
for Remote Power Feed mode. This is followed by the warning
NTU
LOCAL
POWER
REQUIRED,
PROCEED ANYWAY
(Y/N)
.
This will allow the remote unit to be powered from one loop, but will
limit distance.
Remote Console
Screen Access
Select whether system settings can be made from the NTU console
screen or the settings are read-only. This option is set only at the LTU.
ALLOWED
NTU console screens can be used to make system settings.
BLOCKED
NTU console screens are read-only. The LOC and REM pushbuttons
on the NTU are also disabled. System settings can be made only from
the LTU console screen. A remote user is unable to log on, either
initially or after quitting the screen, if the system setting is set to
BLOCKED. If the system setting is changed to BLOCKED while the
remote user is logged on, the screen changes to read-only.
Protection Switch
Command
Not supported.
Table 4.
Settings in Config System Settings Menu (Cont.)