Using the Maintenance Terminal
150-402-102-01, Revision 01
28
July 27, 1998
HRU-402 List 2
System Settings
The System Settings screen allows you to analyze and view configurable
parameters set at the HLU. These screens are for viewing only and cannot be
altered. The system settings can only be set at the HLU.
1
Type
from either the Maintenance Terminal Main Menu or the
Remote Terminal Main menu to view the System Settings screen:
Figure 14.
System Settings Screen
2
View HRU-402 List 2 system settings. Change system settings at the
HLU connected to the remote unit.
3
Type
to set the default settings.
4
Type
exit and return to the previous screen.
lists the System Settings fields and descriptions.
SYSTEM SETTINGS
TIME: 12:46:06
DATE: 02/02/98
CIRCUIT ID#:
A. EQUALIZATION....: EXT
P. MARGIN ALARM THRESH: 4
B. SMART-JACK LPBK.:ENABLED
Q. RLOS (DS1 LOS)ALARM: ENABLED
C. SPECIAL LPBK....: GNLB
R. ALARM PATTERN......: AIS
F. POWER...........: AUTO
S. BPVT...: DISABLED
G. ZBTSI...........: OFF
H. BER ALARM THRESH: NONE
I. LOOPBACK TIMEOUT: 60
J. ALARM...........: DISABLED
K. DS1 LINE CODE...: AUTO
L. FRAMING.........: AUTO
M. AIS ON HDSL LOSW: 2 LOOPS
N. AIS ON SMJK/NREM: ENABLED
O. DS0 BLOCKING: xx = Blocked Channels
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
(D)efaults, (E)xit
Enter the option letter to change setting
(C)onfirm