Maintenance
150-431-115-01, Revision 01
24
September 22, 1998
HLU-431 List 1E
System Settings Screen Options
describes the System Settings screen options and their counterpart codes for the front panel display.
Table 9.
HLU-431 List 1E System Settings Screen Options
System Settings
Screen Options
Front Panel
Display
Code
Selection
Description
Equalization
EQL
0*
Sets the Equalizer to DSX-1 for 0 to 133 feet.
133
Sets the Equalizer to DSX-1 for 133 to 266 feet.
266
Sets the Equalizer to DSX-1 for 266 to 399 feet.
399
Sets the Equalizer to DSX-1 for 399 to 533 feet.
533
Sets the Equalizer to DSX-1 for 533 to 655 feet.
SmartJack Loopback LBPK
DIS
Configures the HiGain system to ignore all in-band SmartJack loopback
commands.
ENA*
Enables the HiGain system to recognize all in-band SmartJack loopback
commands.
Special Loopback
SPLB
GNLB*
Configures the HiGain system to respond to the generic (3- or 4-in-7) in-band
loopback codes.
A1LB and
A2LB
Configures the HiGain system to respond to the in-band loopback codes of the
Teltrend addressable repeater.
A3LB
Configures the HiGain system to respond to the in-band loopback codes of the
Wescom addressable repeater.
A4LB
Configures the HiGain system to respond to the in-band loopback codes of the
Wescom Mod 1 addressable repeater.
A5LB
Configures the HiGain system to respond to the in-band loopback codes of the
Teltrend Mod 1 addressable repeater.
Power
PWRF
DIS
Disables powering to the HDSL pair.
ENA*
Allows the HDSL line voltage to automatically switch between -140V
maximum for non-doubler applications and
±
100V for doubler applications.
ZBTSI
ZBTS
ON
Tells the HiGain system that the ESF frame is operating in its Zero-Byte
Timeslot Interchange (ZBTSI) mode.
OFF*
Tells the HiGain system that the ESF frame is operating in its normal
non-ZBTSI mode.
ES Alarm Threshold
ESAL
17
Activates (closes) the minor alarm relay contacts on pins 20 and 21 and
flashes the red STATUS LED when 17 errored seconds (ES) occur within a
24-hour period.
170
Activates (closes) the minor alarm relay contacts on pins 20 and 21 and
flashes the red STATUS LED when 170 errored seconds (ES) occur within a
24-hour period.
NONE*
Prevents generation of a minor alarm due to errored seconds.
*Indicates factory default settings.