PairGain 150-1353-43 Technical Practice Download Page 12

Troubleshooting

 

 363-753-143-01, Revision 01

8

April 25, 2000

 FRC-753 List 4C

C

USTOMER

 R

EPORTED

 P

ROBLEMS

Table 2

 provides troubleshooting procedures based on customer reported problems.

Table 2.

FRC-753 RT Channel Unit Troubleshooting

Problem

Cause

Action

No dial tone, 
cannot dial

faulty RT or COT Channel 
Unit

facility short/open

CO switch problem

Lift the subscriber pair at the network interface. If dial tone is present and you 

can place a call, refer the problem to the customer per local practice.

If you cannot hear dial tone or cannot place a call at the network interface (with 

the subscriber pair lifted), check for dial tone at the RT. If dial tone is present, 
check the pair between the RT and the network interface. If no dial tone is 
present, replace the RT Channel Unit.

If the problem still exists, re-insert the original RT Channel Unit and replace the 

COT Channel Unit. Test for operation.

If the problem still exists, refer the problem to the CO switch.

Phone does 
not ring

high-resistance subscriber 
line short

faulty RT or CO Channel 
Unit

•loop length too long

Lift the subscriber pair at the network interface. If ringing is present, refer the 

problem to the customer per local practice.

If ringing is not present, check for ringing at the RT. If ringing is present, check 

the pair between the RT and the network interface. If no ringing is present, 
replace the RT Channel Unit. If ringing is still not present, check a circuit on 
another Channel Unit. If ringing is still not present, replace the RTLU.

If ringing is still not present at the RT, re-insert the original Channel Unit and 

Line Unit. Test for ringing at the COT shelf.

Test for ringing into the COT from the CO switch. If no ringing is present, refer 

the trouble to the CO switch. If ringing is present, replace the COT Channel Unit. 
Test again for ringing at the network interface. If ringing is still not present, 
contact PairGain technical assistance (refer to 

“Limited Warranty” on page 11

).

Verify the resistance of the copper loop between the RT Enclosure and the 

network interface is less than 530 

.

Phone does 
not stop 
ringing

faulty subscriber 
instrument

faulty RT Channel Unit

loop length too long

Test for ring trip at the network interface. If the ringing is tripped, refer the 

trouble to the customer per local practice.

If the ringing is not tripped, test for tripping at the RT. If ring trip does occur, 

check the loop for excessive length. If ring trip does not occur, replace the RT 
Channel Unit. If ring trip still does not occur, contact PairGain technical 
assistance (refer to 

“Limited Warranty” on page 11

).

Verify the resistance of the copper loop between the RTE and the network 

interface is less than 530 

.

Cannot 
hear, cannot 
be heard

subscriber problem

faulty RT or COT Channel 
Unit

Lift the subscriber line at the network interface and check the signal level. If 

correct, refer trouble to the customer per local practice.

If the level is too low, check the level at the RT. If the level is correct at the RT, 

check the pair between the RT and the network interface. If the level is too low 
at the RT, replace the RT Channel Unit.

If the level is still too low, re-insert the original RT Channel Unit.

Check the level at the COT shelf coming from the CO switch. If it is correct, 

replace the COT Channel Unit. If it is not correct, refer the problem to the CO 
regarding the switch.

If the level is still not correct, re-insert the original COT Channel Unit. Contact 

PairGain technical assistance (refer to 

“Limited Warranty” on page 11

).

Summary of Contents for 150-1353-43

Page 1: ...CTICE PairGain 1 A C T I V E 2 3 4 5 6 7 8 FAULT FRC 753 CHAN UNIT LIST Eight Channel LoopStart GroundStart Remote Terminal Model FRC 753 List 4C Part Number 150 1353 43 CLEI Code VARHCKTCAB 363 753 1...

Page 2: ...ed trademarks of their respective companies Information contained in this document is company private to PairGain Technologies Inc and shall not be modified used copied reproduced or disclosed in whol...

Page 3: ...PairGain Order replacement equipment if necessary Check the packing list to ensure complete and accurate shipment of each listed item If the shipment is short or irregular contact PairGain as describ...

Page 4: ..._________________________________________ 6 Installing the FRC 753 into the RT Enclosure 6 Provisioning the FRC 753 6 Verify Operation 6 Troubleshooting _______________________________________________...

Page 5: ...ubscriber line connection through an optional metallic bypass pair Perform metallic bypass testing either manually or through the Pair Gain Test Controller PGTC Features of the FRC 753 are eight LS GS...

Page 6: ...criber Each FRC 753 detects loop current Ring tip Ring ground The subscriber line battery is supplied by a constant current supply It is sufficient to operate a telephone set over the indicated loop T...

Page 7: ...ition is a Tip lead open and Ring lead negative into the COT and Tip lead open and Ring lead negative at the RT The following occurs when a PBX requests service for an outgoing call by grounding the R...

Page 8: ...ower at the RT the LEDs extinguish after a 2 minute timeout period Press and hold the ACO button on the RTLU for two seconds to re activate the LEDs for another two minutes Table 1 FRC 753 Front Panel...

Page 9: ...r Output 40 V RMS 3 lines simultaneous 5 REN each End to End Loss 2 5 dB 1 0 dB Lightning Protection GR CORE 1089 Section 4 Environmental Operating Elevation 200 ft to 13 000 ft 60 m to 4 000 m Temper...

Page 10: ...is off no calls are in progress 2 Test circuits for loop start a Place an outgoing call for each subscriber circuit provisioned and observe that the Active LED tracks the progress of the call b Place...

Page 11: ...this connection to the COT where it can be switched onto the test access bus or to the corresponding subscriber line on the COT channel card Activate test access through the RS 232 maintenance port l...

Page 12: ...ing into the COT from the CO switch If no ringing is present refer the trouble to the CO switch If ringing is present replace the COT Channel Unit Test again for ringing at the network interface If ri...

Page 13: ...Services CO Central Office COLU Central Office Line Unit COT Central Office Terminal DTMF Dual Tone Multi Frequency LS GS Loop Start Ground Start MLT Mechanized Loop Testing PBX Private Branch Exchan...

Page 14: ...Abbreviations 363 753 143 01 Revision 01 10 April 25 2000 FRC 753 List 4C...

Page 15: ...e software furnished with its products will operate substantially in accordance with the PairGain published specifications and documentation for such software PairGain s entire liability for software...

Page 16: ...following information in writing along with the equipment you are returning Company name and address Contact name and telephone number The shipping address to which PairGain should return the repaired...

Page 17: ...quency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely...

Page 18: ...Corporate Office 14402 Franklin Avenue Tustin CA 92780 Tel 714 832 9922 Fax 714 832 9924 For Technical Assistance 800 638 0031 714 730 3222...

Reviews: