PairGain 150-1304-21 Manual Download Page 13

363-704-121-01, Revision 01

 

Installation and Test

FLC-704 List 2A

July 30, 1999

 7

 

Table 2.

FLC-704 Troubleshooting

Indication

Problem

Action

FAULT LED ON

The FLC-704 processor has 
detected a fault.

Remove and re-insert the FLC-704. If the FAULT LED does not extinguish, replace 
the FLC-704.

Troubleshooting based on customer-originated trouble reports

No dial tone, Can 
not dial

faulty RT or COT Channel 
Unit

facility short/open

CO switch problem

1

Lift the subscriber pair at the network interface. If the dial tone is present and 
you can place a call, refer the problem to the customer per local practice.

2

If you cannot hear dial tone or cannot place a call at the network interface (with 
the subscriber pair lifted), check for dial tone at the RT. If dial tone is present, 
check the pair between the RT and the network interface. If no dial tone is 
present, replace the RT Channel Unit.

3

If the problem still exists, re-insert the original RT Channel Unit and replace the 
COT Channel Unit. Test for operation.

4

If the problem still exists, refer the problem to the CO switch.

Phone does not 
ring

high-resistance subscriber 
line short

faulty RT or CO Channel 
Unit

loop length too long

1

Lift the subscriber pair at the network interface. If ringing is present, refer the 
problem to the customer per local practice.

2

If ringing is not present, check for ringing at the RT. If ringing is present, check 
the pair between the RT and the network interface. If no ringing is present, 
replace the RT Channel Unit. If ringing is still not present, check a circuit on 
another Channel Unit. If ringing is still not present, replace the Lin eUnit.

3

If ringing is still not present at the RT, re-insert the original Channel Unit and 
Line Unit. Test for ringing at the COT.

4

Test for ringing into the COT from the CO switch. If no ringing is present, refer 
the trouble to the CO switch. If ringing is present, replace the COT Channel Unit. 
Test again for ringing at the network interface. If ringing is still not present, 
contact PairGain technical assistance per 

“Warranty” on page 9

.

5

Verify the resistance of the copper loop between the RT Enclosure and the 
network interface is less than 530 

.

Phone does not 
stop ringing

faulty subscriber 
instrument

faulty RT Channel Unit

loop length too long

1

Test for ring trip at the network interface. If the ringing is tripped, refer the 
trouble to the customer per local practice.

2

If the ringing is not tripped, test for tripping at the RT. If ring trip does occur, 
check the loop for excessive length. If ring trip does not occur, replace the RT 
Channel Unit. If ring trip still does not occur, contact PairGain technical 
assistance per 

“Warranty” on page 9

.

3

Verify the resistance of the copper loop between the RT Enclosure and the 
network interface is less than 530 

.

Can not hear, 
Can not be heard

subscriber problem

faulty RT or COT Channel 
Unit

1

Lift the subscriber line at the network interface and check the signal level. If 
correct, refer trouble to the customer per local practice.

2

If the level is too low, check the level at the RT. If the level is correct at the RT, 
check the pair between the RT and the network interface. If the level is too low 
at the RT, replace the RT Channel Unit.

3

If the level is still too low, re-insert the original RT Channel Unit.

4

Check the level at the COT coming from the CO switch. If it is correct, replace 
the COT Channel Unit. If it is not correct, refer the problem to the CO regarding 
the switch.

5

If the level is still not correct, re-insert the original COT Channel Unit. Contact 
PairGain technical assistance per 

“Warranty” on page 9

.

Summary of Contents for 150-1304-21

Page 1: ...E CHANNEL UNIT PAIRGAIN TECHNOLOGIES INC ENGINEERING SERVICES TECHNICAL PRACTICE SECTION 363 704 121 01 Model List Number Part Number CLEI Code FLC 704 2A 150 1304 21 PairGain FLC 704 CHAN UNIT LIST F...

Page 2: ...in this document is company private toPairGain Technologies Inc and shall not be modified used copied reproduced or disclosed in whole or in part without the written consent of PairGain Other product...

Page 3: ...ing list to ensure complete and accurate shipment of each listed item If the shipment is short or irregular contact PairGain as described in the Warranty If you must store the equipment for a prolonge...

Page 4: ...Inspecting Your Shipment 363 704 121 01 Revision 01 iv July 30 1999 FLC 704 List 2A...

Page 5: ...__________________________________________________ 4 Subscriber Drop Testing 4 Installation and Test___________________________________________________________________ 6 Unpacking the FLC 704 6 Turn U...

Page 6: ...Table of Contents 363 704 121 01 Revision 01 vi July 30 1999 FLC 704 List 2A...

Page 7: ...ing The FLC 704 Channel Unit includes green status LEDs for each line indicating idle ringing and off hook conditions as well as a red LED indicating a fault condition The channel unit provides metall...

Page 8: ...Panel Table 1 FLC 704 Front Panel LEDs LED LED State Indicates Solid green Channel is off hook ACTIVE Fast flashing green Channel is in test access mode 1 through 8 Slow flashing green Channel is ring...

Page 9: ...1 0 dB DC Off Hook Current 30 mA Channel Signature Tip Ring 475 k 1 Tip Ground 332 k 1 Ring Ground open COT 20 Hz Input Impedance 0 5 REN Environmental Operating Elevation 200 ft to 13 000 ft 60 m to...

Page 10: ...made through the maintenance terminal or by the CO switch applying the appropriate voltages on the subscriber line as described in the Subscriber Drop Testing section SUBSCRIBER DROP TESTING For subs...

Page 11: ...4 List 2A July 30 1999 5 Figure 2 FLC 704 Block Diagram Test Line Access Test in Test out Line 1 Tip Ring Line 8 Tip Ring Subscriber Line Interface Circuits SLICs CODEC Line unit interface Front panel...

Page 12: ...store the equipment for a prolonged period store the equipment in its original container TURN UP AND TESTING Install COT Channel Units 1 Insert each FLC 704 into the COT shelf All LEDs on the Channel...

Page 13: ...annel Unit and Line Unit Test for ringing at the COT 4 Test for ringing into the COT from the CO switch If no ringing is present refer the trouble to the CO switch If ringing is present replace the CO...

Page 14: ...704 List 2A ABBREVIATIONS CO Central Office COT Central Office Terminal DTMF Dual Tone Multi Frequency HDSL High bit rate Digital Subscriber Line PCM Pulse Code Modulation POTS Plain Old Telephone Se...

Page 15: ...and regular maintenance PairGain will repair or replace any unit without cost during this period if the unit is found to be defective for any reason other than abuse or improper use or installation Do...

Page 16: ...s Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Refer to the installa...

Page 17: ...Corporate Office 14402 Franklin Avenue Tustin CA 92780 Tel 714 832 9922 Fax 714 832 9924 For Technical Assistance 800 638 0031...

Reviews: