Monitoring the HDSL System
150-451-104-02, Revision 02
16
September 18, 1998
HDU-451 List 4
C
ONNECTING
TO
THE
T
ERMINAL
To connect a dumb terminal:
1
Connect a standard 9-pin serial terminal cable to the Craft port on the
HDU-451.
shows the pinouts for the Craft port.
2
Connect the other end of the cable to the 9-pin COM port of the dumb
terminal or PC. The terminal is configured as Data Circuit-Terminating
Equipment (DCE).
3
Configure the terminal to the following settings:
•
1200 to 9600 baud (9600 is recommended)
•
No parity
•
8 data bits
•
1 stop bit
•
Hardware Flow Control set to None
•
VT Terminal Emulation
L
OGGING
O
N
AND
U
SING
THE
T
ERMINAL
M
ENUS
When you log on to the terminal menus, the terminal is actually logged on to
the HLU line unit connected to the HDU-451. All system status information
comes from the HLU, eliminating the need to store redundant information at
each doubler in a HiGain system. Because of this, only one doubler can be
logged on to the HLU at any time. The HDU-451 automatically logs off of
the terminal after five minutes of inactivity (no keyboard input).
If you are using the Microsoft Windows terminal emulation
program, from the Settings, Terminal Preference menu, you
must deselect
Show Scroll Bars and Use Function, Arrow, and
Ctrl Keys for Windows.