150-319-151-01, Revision 01
Appendix A - Specifications
HLU-319 List 5A
September 17, 1999
55
Power Consumption with Doublers
through
list the power consumed and dissipated by the HLU-319 when it is used with any of
the four basic doubler types in the HiGain family. The maximum current drawn by the CO supply is also listed.
through
shows power parameters for single doubler, line-powered circuits on 9 kft, 26 AWG
loops.
Table 18.
HLU-319 Power Parameters—Single Doubler (HDU-451 List 1 or 2)
HRU Model No.
HRU CPE
Power
42.5 Vdc Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 Vdc Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-412 List 1, 2, 3, 4
ON
27.5
30.3
7.6
8.4
646
711
HRU-412 List 1, 2, 3, 4
OFF
25.9
28.5
7.2
7.9
610
671
HRU-412 List 6, 7, 8
ON
27.7
30.5
7.6
8.4
651
716
HRU-412 List 6, 7, 8
OFF
24.3
26.7
7.1
7.8
571
628
HRU-402
N/A (OFF)
21
23.1
6.3
6.9
494
543
HRU-411
OFF
20
22.0
6.2
6.8
471
518
Table 19.
HLU-319 Power Parameters—Single Doubler (HDU-439 or HDU-437 Lists 1 and 1B)
HRU Model No.
HRU CPE
Power
42.5 Vdc Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 Vdc Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-412 List 1, 2, 3, 4
ON
22.3
24.5
7.9
8.6
525
578
HRU-412 List 1, 2, 3, 4
OFF
21.4
23.5
7.8
8.5
502
552
HRU-412 List 6, 7, 8
ON
22.3
24.5
8.0
8.8
524
576
HRU-412 List 6, 7, 8
OFF
19.2
21.1
7.3
8.1
452
497
HRU-402
N/A (OFF)
16.0
17.6
6.7
7.4
376
414
HRU-411
OFF
15.6
17.2
6.7
7.4
367
404
Table 20.
HLU-319 Power Parameters—Single Doubler (HDU-409 List 2, HDU-407 List 2, and HDU-404 List 2)
HRU Model No.
HRU CPE
Power
42.5 Vdc Power
Consumption (Watts)
Heat Dissipation (Watts)
42.5 Vdc Current (mA)
Typical
Maximum
Typical
Maximum
Typical
Maximum
HRU-412 List 1, 2, 3, 4
ON
18.8
20.7
7.0
7.7
442
486
HRU-412 List 1, 2, 3, 4
OFF
18.0
19.8
7.1
7.8
424
466
HRU-412 List 6, 7, 8
ON
18.4
20.2
6.9
7.6
433
476
HRU-412 List 6, 7, 8
OFF
15.7
17.3
6.8
7.4
370
407
HRU-402
N/A (OFF)
12.5
13.8
5.9
6.5
294
323
HRU-411
OFF
12.0
13.2
5.8
6.4
283
311