3
4
5
6
7
8
Place wings in freezer.
(Do not freeze vibration unit). Leave in until frozen solid
(~30-60 minutes). Remove wings from freezer just prior to
use. Wings stay frozen for ~10 minutes at room temp.
Note:
To transport, place between 2 commercial cold packs
(sold separately) in an insulated environment to maintain
frozen temperature.
Why Frozen?
Our unique formula freezes solid to transmit vibration;
commercial gels absorb the specific vibration frequency
needed for pain. Ice provides up to 60% of the numbing,
because intense cold causes the brain to inhibit pain
everywhere.
Attach wings to back of
Buzzy®.
Flip switch or press
button firmly to
activate.
Buzzy® controls pain on contact.
Place directly on injury or “between the brain and the pain”
for procedures.
For Injections:
Place Buzzy
®
directly on the injection site for 30-120 seconds.
Leave on longer for larger volumes or more painful injections.
Move 2-3 cm proximal during injection and press in place.
Closer to the injection is better.
TIP: Place Buzzy
®
’s bigger rounded end as close as possible to
the site of the procedure, with Buzzy
®
’s switch end furthest
away. During the injection, move Buzzy
®
2-3 cm toward the
spine along nerve paths (dermatomes) as shown.
Why Does Placement Matter?
Vibration and cold are transmitted together to the same
place in the spine as pain. To block pain, Buzzy
®
needs
to be on the same nerve paths as the source of the pain.
For finger sticks or
splinter removal:
Press Buzzy
®
onto the palm
with the bottom end toward
the finger. Leave in place
throughout cleaning and
during the procedure.
For burning or itching:
For insect bites or medications
that cause burning or itching,
put Buzzy
®
directly on the site.
Rub or press in place until the
area feels better.
For injections in the
stomach:
Place the injection on a
horizontal line between the
belly button and Buzzy
®
.
For IVs or phlebotomy:
Do not put directly on the site
of access.
Activate, then hold or tuck
Buzzy
®
under the tourniquet
3-5 cm above (proximal to)
the access site. Clean site and
access without delay. Optional:
Pass tourniquet through the
slot of Buzzy
®
XL to secure
Buzzy
®
to arm.
For children:
Let children hold Buzzy
®
in advance for familiarity, and
let them choose whether or not to use the ice pack. For
vaccinating children sitting up, a parent can put an arm
around the child’s shoulders and hold Buzzy
®
for them.
Directions For Use:
Buzzy
®
Placement:
T8
T9
T10
T11
T12
L1
L4
L3
L2
L1
T12 T11
C5-6
T1
For additional placement information,
please visit: bzy.fyi
1
2
3
4