background image

indicator, the UV sterilization/strain decomposition indicator, and the child lock indicator.

The dot is an alarm indicator, and the alarm light is lit in the event of a stall or abnormal

high temperature.

Grinding and drying work button:

In the state of no open child lock, after a long press for 3 seconds to open, a "drip"

sound is emitted, and the device enters the grinding and drying working mode.

1、A "Dribble" prompt sound is emitted, and the machine enters working mode. The

working LED is on.

2、The first step is drying, the motor drives the metal blade to rotate slowly (35 seconds

positive -" 50 seconds stop -" 35 seconds reverse) metal blade 2.5r/min cycle, heating

control heating plate temperature to 110 degrees, exhaust fan began to work. The air

outlet temperature is constant at 65 degrees and the humidity is lower than 60 to enter

the next process;

3、The second part is crushed, and the motor drives the metal blade to rotate rapidly

(45 seconds forward rotation -" 35 seconds stop -" 45 seconds reverse) metal blade

about 3.5r/min cycle cycle, heating control heating plate temperature 110 degrees,

exhaust fan has been working, control the temperature in the barrel, air outlet

temperature is constant at 70 degrees and humidity is less than 10% to enter the next

process;

4、The third step is cooling, heating off, fan on, UV lamp cycle start and stop (30min per

hour, stop 30min), while the motor drives the metal blade to rotate slowly (60 seconds

positive -" 10 seconds stop -" 60 seconds reverse) metal blade 3.5r/min cycle, the air

Summary of Contents for HQD-314

Page 1: ...kitchen waste disposer Product manuals The version number V1 0 0...

Page 2: ...ame Kitchen waste disposer Model HQD 314 Please read this product manual carefully before using the product and keep it safe for easy reference at any time If the equipment is damaged due to failure t...

Page 3: ...Directory One Product overview 4 Two Product specifications 4 Three Operating instructions 5 3 1 Button action 5 3 1 App usage instructions 9 Four Precautions 10 Five Questions and answers 11...

Page 4: ...he environment and the unique air purification system of the equipment uses high efficiency activated carbon to filter and UV lamp sterilization The high grade board contains microbial degradation thr...

Page 5: ...s the indicator light which is the working Opening method Touch the button Action tips buzzer buzzer buzzer Device status is displayed Light Whether UV sterilization is supported Support Auto Manual S...

Page 6: ...ng control heating plate temperature to 110 degrees exhaust fan began to work The air outlet temperature is constant at 65 degrees and the humidity is lower than 60 to enter the next process 3 The sec...

Page 7: ...exhaust fan starts working Heating controls the heating plate temperature to 80 degrees At the same time the motor drives the metal blade to rotate slowly when the UV lamp stops 35 seconds positive 35...

Page 8: ...min cycle 3 Wait for the humidity to be constant below 30 to finish the work and make a drip sound to prompt the end of the 5 times Open cover button In the state of no opening child lock after a lon...

Page 9: ...minutes the temperature in the barrel is controlled to 30 degrees 3 1App usage instructions For the time being only support Android system after installing the APP open Bluetooth and enter the APP 1 C...

Page 10: ...pment Four Precautions 1 Do not release hard objects or large bones which may cause the stirring tip to break 2 Be careful not to put too much water in the garbage 3 During the working hours of the eq...

Page 11: ...1 kWh of electricity 2 How noisy is the operation A Less than 48 dB 3 How long does it take to turn food waste into drying and grinding A It generally takes 4 6 hours and the moisture is longer 4 Act...