6
File: R10502-8
2015-12-03 ASA
Maxi-Flo
R
10
9
11
12
13
1
3
2
4
5
7
6
8
5
5
V
vx
l M
F
T
6
80
M
ax
i-F
lo
2
00
kW
M
12
3
5
2
-
B
o
rr
in
st
ru
kt
io
n
A
20
7
7
0
17
222
B
3
P
7
Q:\Mekanik\Mek-ritningar\M12352.idw
MFT680, A=340
MFT1020, A=800
Montering:
- Montera det övrefästet på väggen med minst tre skruvar.
- Montera det nerdre fästet i det avlånga hålet enligt skissen.
- Häng upp värmeväxlaren och skjut upp det nedre fästet tills
värmeväxlaren ligger an mot fästet.
- Markera för minst tre av de runda hålen och lyft ned
värmeväxlaren.
- Fäst det nedre fästet i minst tre av de runda hålen.
- Häng upp värmeväxlaren.
- Montera flänsarna enligt monteringsanvisning.
A
H
Heat exchanger Maxi-Heat Titanium
MA40-15E
ENGLISH
1. Heat exchanger
2. Boiler, storage tank or heat pump
3. Primary hot water circuit
4. Thermostat
5. Cutoff valve
6. Check valve
7. Circulation pump
8. Secondary circuit (pool water)
9. Filter
10. Pump
11. From the pool
12. Return to the pool
13. Drain outlet
Installation
Place the heat exchanger as in the drawing.
When installed above the pool water, the pipes should be laid in the loop, so that the heat exchanger cannot get self-drained.
Dosing of chlorine, acid or similar substances must always be done AFTER the heat exchanger.
If the pool circulation is terminated or suspended, the circulation pump on the primary side shall be switched off.
At the risk of freezing and if the pool is closed for the winter for longer than 1 month, the heat exchanger must be drained of
all water.
Mounting
Measure and mark where the heat exchanger is to be located.
Wall fixture should be mounted on a solid, flat surface/wall.
Modell MFT260
1. Mount the supplied wall brackets onto the wall.
2. Insert a strap into every wall mount.
3. Hold the heat exchanger and tighten the straps around it.
Model MFT680
1. Insert the supplied wall brackets as is shown in Fig.2.
Mount the top bracket with three screws in the round holes.
Mount the bottom bracket first into the hole with a screwdriver.
2. Hang up the heat exchanger.
Slide up the bottom bracket until the heat exchanger lies against the fixture.
Mark at least three of the round mounting holes and put down the heat exchanger.
Fasten the lower fixture (at least three of the round holes).
3. Hang up the heat exchanger.
4. Mount the self-adhesive gaskets for heat exchanger tube spigots.
5.
Place the detachable flange onto the heat exchanger tube
spigot, see Fig. 3.
Drag the screws through the flanges and make sure
that the screws on the left side of the heat exchanger
go through the hole in the wall bracket (A).
6. Tighten the screws (with a washer and nut)
with a torque of 30 Nm.
Flange sleeve (2x)
Heat exchanger connection
This flange and collar
sleeve not supplied.
Packing
self-adesive surface against
the heat exchanger
Screw M16x80 (4x)
Washer M16 (4x)
Washer M16 (4x)
Nut M16 (4x)
Pic. 3
Pic. 2