background image

6

File: R10502-8

2015-12-03 ASA

Maxi-Flo

R

10

9

11

12

13

1

3

2

4

5

7

6

8

5

5

V

vx

l M

F

T

6

80

 M

ax

i-F

lo

 2

00

kW

M

12

3

5

2

 -

 B

o

rr

in

st

ru

kt

io

n

A

20

7

7

0

17

222

B

3

P

7

Q:\Mekanik\Mek-ritningar\M12352.idw

MFT680, A=340
MFT1020, A=800

Montering:
- Montera det övrefästet på väggen med minst tre skruvar.
- Montera det nerdre fästet i det avlånga hålet enligt skissen.
- Häng upp värmeväxlaren och skjut upp det nedre fästet tills 
värmeväxlaren ligger an mot fästet.
- Markera för minst tre av de runda hålen och lyft ned 
värmeväxlaren.
- Fäst det nedre fästet i minst tre av de runda hålen.
- Häng upp värmeväxlaren.
- Montera flänsarna enligt monteringsanvisning.

A

H

Heat exchanger Maxi-Heat Titanium

MA40-15E

ENGLISH

  1.  Heat exchanger
  2. Boiler, storage tank or heat pump
  3. Primary hot water circuit
  4. Thermostat
  5. Cutoff valve
  6. Check valve
  7. Circulation pump
  8. Secondary circuit (pool water)
  9. Filter
10. Pump
11. From the pool

12. Return to the pool

13. Drain outlet

Installation

Place the heat exchanger as in the drawing.

When installed above the pool water, the pipes should be laid in the loop, so that the heat exchanger cannot get self-drained.
Dosing of chlorine, acid or similar substances must always be done AFTER the heat exchanger.

If the pool circulation is terminated or suspended, the circulation pump on the primary side shall be switched off.
At the risk of freezing and if the pool is closed for the winter for longer than 1 month, the heat exchanger must be drained of  
all water.

Mounting

Measure and mark where the heat exchanger is to be located.

Wall fixture should be mounted on a solid, flat surface/wall.

Modell MFT260

1.  Mount the supplied wall brackets onto the wall.
2.  Insert a strap into every wall mount.
3.  Hold the heat exchanger and tighten the straps around it.

Model MFT680

1.  Insert the supplied wall brackets as is shown in Fig.2.  

Mount the top bracket with three screws in the round holes.  

Mount the bottom bracket first into the hole with a screwdriver.

2.  Hang up the heat exchanger. 

Slide up the bottom bracket until the heat exchanger lies against the fixture.

 

Mark at least three of the round mounting holes and put down the heat exchanger. 

Fasten the lower fixture (at least three of the round holes).

3.  Hang up the heat exchanger.
4.  Mount the self-adhesive gaskets for heat exchanger tube spigots.
5. 

Place the detachable flange onto the heat exchanger tube 

 

spigot, see Fig. 3.  

Drag the screws through the flanges and make sure

 

that the screws on the left side of the heat exchanger  
go through the hole in the wall bracket (A). 

6.  Tighten the screws (with a washer and nut) 

with a torque of 30 Nm.

Flange sleeve (2x)

Heat exchanger connection

This flange and collar 

sleeve not supplied.

Packing

self-adesive surface against  

the heat exchanger

Screw M16x80 (4x)

Washer M16 (4x)

Washer M16 (4x)

Nut M16 (4x)

Pic. 3

Pic. 2

Reviews: