Spotlight LED 60 Classic
MA50-10E
ENGLISH
page 8 of 20
12VAC
All lamps are connected to the transformer via 1 cable
Wiring instructions Setup 2
page 10 of 20
12VAC
Installation general
The recommended depth is described in the subsequent sections.
•
Reinforcement should never be closer than at least 50 mm from stainless steel in the cast-coated pool constructions.
•
Electrical installations >30V must not be placed within 500 mm distance from any stainless steel material.
•
During installation works, stainless steel tools with clean contact surfaces should be used.
• In order to avoid scratches and stains, keep the items in their original packaging until installation.
• Be careful during installation, so as not to scratch the item.
•
Avoid placing concentrated chemical dosages next to stainless steel details. Damage can occur in case of no pool circulation.
Electric installations
Observe local electrical regulations regarding location of the dosage connections.
The lighting must always be connected via a transformer protection 12V AC of the ring core type (see tables below) for correct
operation and maximum service life.
The supplied cord should always be used for LED connection.
If the external cable insulation or inner conductor of the lighting is damaged, replace it with a service technician or other
authorized person.
Recommendations
In order to get the desired function, the following recommendations for cables and lights connection should be followed.
Maximum and steady light is guaranteed only if the cable cross section is equal to or exceeds the values in the tables.
The cable lengths are calculated on account of the greatest possible power loss in the cables.
Min. cable length is 4 m.
The transformer’s rated power must be equal to or greater than the rated power sum of the connected lamps.
Option 1
Item no. Color
Max cable length / Cable cross section
Transformer power [VA]*
1,5 mm
2
2,5 mm
2
4,0 mm
2
6,0 mm
2
125840 Warm white
77 m
129 m
207 m
311 m
16
125841 Cold white
77 m
129 m
207 m
311 m
16
125842 RGB
62 m
103 m
165 m
248 m
12
Option 2.
Item no. Color
Quantity of
lamps
Max cable length / Cable cross section
Transformer power [VA]*
2,5 mm
2
4,0 mm
2
6,0 mm
2
10,0 mm
2
125840 Warmwhite
125841 Cold white
1
129 m
207 m
311 m
519 m
16
2
64 m
103 m
155 m
259 m
32
3
43 m
69 m
103 m
173 m
64
4
32 m
51 m
77 m
129
128
125842 RGB
1
103 m
165 m
248 m
414 m
12
2
51 m
82 m
124 m
207 m
24
3
34 m
55 m
82 m
138 m
36
4
25 m
40 m
62 m
103 m
48
Max cable length
230VAC
4m cable, supplied for the lamp
A separate cable not included.
Option 1.
This solution is preferable for new instal
-
lations where channels location is not
complete.
All lights are connected directly to the
transformer with a separate cable
Kopplings-
box
Kopplings-
box
Max cable length
230VAC
4m cable, supplied for the lamp
A separate cable not included
Option 2.
All lamps are connected to the transformer via power cable and
coupling box