background image

16

number of charge/discharge cycles; voltage; full
capacity in Ah; date of manufacture and firmware
version.

7.1

Over-charge Protection

Charging will be inhibited if the battery voltage
exceeds a pre-set level.

7.2

Over-discharge Protection

When the battery voltage reaches 12.5V, discharging
is inhibited.

7.3

Over-current Protection

If a single battery is subjected to a current greater
than 8A (for the V-Mount Model) or 10A (for the Gold
Mount model) but less than 15A, the output will be
turned off after 5 seconds. If the current is greater
than 15A, the output will be turned off immediately.
In either case, the battery display will be inoperative
and there will be no voltage available at the
terminals. The battery can be reset by removing it
from the load and pressing the display button.

7.4

Thermal Protection

Software protection inhibits charging if the battery
temperature is below 0°C. Return the battery to the
charger when the battery temperature rises above 0°C.

Software protection inhibits discharging if the battery
temperature falls to -20°C, or if it rises to +70°C.
The output can be restored when the battery
temperature becomes within the specified range
by pressing the display button.

7. Battery Protection Features

Summary of Contents for PAGlink PL150 Series

Page 1: ...U5130 AUG 2016 INTELLIGENT LINKING BATTERIES PL150 Series V Mount Gold Mount Models Instruction Booklet...

Page 2: ...Battery Contacts PAGlink Latching Mechanism PAGlink Contact Block Display Button PAGlink Contact Shield PAGlink Release Button Battery Contacts Display Button PAGlink Contacts Battery Lock Release But...

Page 3: ...or future reference and to take with you when you travel by air with your PAGlink batteries 3 Contents Section Page 1 Features 4 2 Specification 6 3 Charging 9 4 Discharging 10 5 Storage 11 6 Run Time...

Page 4: ...ge or discharge When linked PAGlink batteries form a network that allows them to communicate with each other and to report to the camera as one large battery The PAGlink system will automatically sele...

Page 5: ...upported Batteries in any state of charge can be linked for charging in multiples of 8 or less During charging the least charged batteries are given priority The charge status for each battery is show...

Page 6: ...ight indicator which shows a run time prediction on load indicated by a combination of lights and capacity as a percentage each light represents 20 2 4 Construction High impact polycarbonate injection...

Page 7: ...10 Charge Voltage 16 8V 2 11 Charge Times Times given are for fully discharged PL150 batteries using a PAGlink PL16 charger After 3 hours 1 battery will be charged to 95 2 12 Protection The battery i...

Page 8: ...ogical advances that PAG introduces to accommodate developments in camera technology An update tool can be provided by PAG 2 14 Temperature Range Charging 0 C to 45 C Optimum 10 to 40 C 32 F to 113 F...

Page 9: ...Chargers 9707A PAGlink PL16 Charger 8 per channel 9711A PAGlink PL16 Charger 8 per channel Anton Bauer Li Ion chargers are also suitable Four or more linked batteries can be charged on each position d...

Page 10: ...ection 2 Specification for the charging temperature range of PAGlink PL150 batteries 4 1 The batteries incorporate a precision fixed end of discharge cutoff set to 12 5V as measured by the battery Thi...

Page 11: ...or 10A for Gold Mount models two or more PAGlink batteries should be linked This will increase the maximum continuous discharge current to 12A 4 6 The battery may be discharged within the tempera ture...

Page 12: ...advisable to give the battery a top up charge before use 6 1 The Numeric Display Models 9309 9313 The battery is able to display a numeric run time prediction against load and charge status as a perc...

Page 13: ...d be charged by pointing to the empty battery symbol 4 When the battery is fully charged the display will indicate 100 6 2 The 5 Light Display Model 9308 The battery is able to indicate a run time pre...

Page 14: ...centage When batteries are linked this figure still relates to the battery s individual capacity The LEDs light clockwise starting from the top right 5 Lights 80 100 remaining 4 Lights 60 79 remaining...

Page 15: ...until RED appears on the numeric display or until the top 2 segments are lit 5 Light indicator This indicates that the battery is now compatible with the RED data protocol reversed SMB When the batter...

Page 16: ...f the current is greater than 15A the output will be turned off immediately In either case the battery display will be inoperative and there will be no voltage available at the terminals The battery c...

Page 17: ...nate injection mouldings designed to protect the cells from impact damage Circuits are coated with Parylene the premier vacuum deposited conformal coating making them resistant to electrolyte Internal...

Page 18: ...18 To release the battery hold down the release button 1 and slide the battery up 2 PAGlink V Mount Terminals Front Terminals...

Page 19: ...19 Base Terminals Rear Terminals...

Page 20: ...Slide the battery across until you hear a click and the white locking indicator is visible on the battery release button 20 To release the battery hold down the release button and slide the battery t...

Page 21: ...21 Rear Terminals Positive Negative PAGlink Comms Viewfinder Data Charger Talk Front Terminals PAGlink Gold Mount Terminals Positive Negative PAGlink Comms Viewfinder Data Reserved...

Page 22: ...r all circumstances The PAGlink management system elects the battery with one or more connected to its front contacts to be the master and ensures that this battery is always active but not necessaril...

Page 23: ...lkaline solution which can cause chemical burns to human tissue if leakage occurs Wear protective gloves when handling all contaminated materials In the event of contact with the skin flood copiously...

Page 24: ...Ltd offers a recycling service for expired PAG batteries which results in the materials being recovered for re use WARNING Do not mutilate or incinerate batteries Do not dispose of batteries or cells...

Page 25: ...in the period of the guarantee provided the guarantor s examination discloses to its satisfaction the product was defective The guarantor may at its option replace the product in lieu of repair With r...

Page 26: ...re made to the products without our approval Product PAGlink PL150 Lithium Ion Batteries Models 9308 9309 9313 Applicable EU Directives EMC Directive 89 336 EU CE Marking Directive 93 68 EU Harmonised...

Page 27: ...ndent testing as required by law The only way to know for sure if the battery has been tested to UN standards is by asking the manufacturer to produce a test report issued by an independent test facil...

Page 28: ...n 2 3 5 9 PL150 Models 9308 9309 Test Report No 102617072 PL150 Model 9313 Test Report No 101520017 In addition to UN testing these Li Ion batteries have an individual Watt hour rating between 100Wh a...