16
number of charge/discharge cycles; voltage; full
capacity in Ah; date of manufacture and firmware
version.
7.1
Over-charge Protection
Charging will be inhibited if the battery voltage
exceeds a pre-set level.
7.2
Over-discharge Protection
When the battery voltage reaches 12.5V, discharging
is inhibited.
7.3
Over-current Protection
If a single battery is subjected to a current greater
than 8A (for the V-Mount Model) or 10A (for the Gold
Mount model) but less than 15A, the output will be
turned off after 5 seconds. If the current is greater
than 15A, the output will be turned off immediately.
In either case, the battery display will be inoperative
and there will be no voltage available at the
terminals. The battery can be reset by removing it
from the load and pressing the display button.
7.4
Thermal Protection
Software protection inhibits charging if the battery
temperature is below 0°C. Return the battery to the
charger when the battery temperature rises above 0°C.
Software protection inhibits discharging if the battery
temperature falls to -20°C, or if it rises to +70°C.
The output can be restored when the battery
temperature becomes within the specified range
by pressing the display button.
7. Battery Protection Features