4
CARE & MAINTENANCE
SECTION 2
1.16 Charger Output Voltage:
40V DC Maximum.
1.17 Output Current:
5Ah Models: 500mA.
7Ah Models 700mA.
10Ah Models 1000mA.
1.18 Charging Indicator:
Indicator is lit when integral charger is operating.
1.19 Safety:
Designed to comply with Electrical Safety Standard BS EN 60335 Part 2 Sec-tion
2.29 Class 2 (double insulated). Charger designed for indoor use only.
UK mains lead fitted with l" fuse to BS 1362 rated 5A.
2.1
STORAGE
Pagbelts can be stored indefinitely in any state of charge (even totally dis-
charged) without significant loss of cell life. Maintenance charging is not
required. Store in a cool, dry place. Ideally the temperature should be from -
20°C to +30°C. High storage temperatures (above +45°C) will reduce the
battery’s life because of unwanted chemical reactions. Excessively low
storage temperatures (below -30°C) are also to be avoided since the
electrolyte may freeze result-ing in permanent cell damage.
After prolonged storage do not fast-charge the battery immediately. The cells
should first be reformed and balanced by giving the battery a slow (C/10)
charge for 24 hours. When the battery is subsequently put into service, 2 or 3
cycles of charge and discharge may be needed to return the battery fully to its
rated capacity.
The battery belt should be in a fully charged state before use. Even after one
week in storage the battery should be given a top up charge before use.
At room temperature (20°C) Nickel-Cadmium batteries lose 1% of their charge
per day. The top-up charge needed is one hour at C/10 for each week of
storage.
2.2
Charge the battery belt only from constant current chargers - see Section 3,
Instructions For Use. Constant voltage chargers must not be used.
2.3
For maximum output, use within the temperature range 0°C to +40°C.