![PAG L95e Instruction Leaflet Download Page 2](http://html1.mh-extra.com/html/pag/l95e/l95e_instruction-leaflet_3232899002.webp)
3.9
The battery is sealed, and contains no user-serviceable components.
In order to maintain the quality standard for which you first chose
this product, return it to a PAG Dealer or the PAG Service Department
for servicing.
4.1
Charging
IMPORTANT: THE BATTERY IS ELECTRONICALLY PROTECTED, AND WILL
NOT ACCEPT A CHARGE FROM UNSUITABLE CHARGERS.
PAGlok Model:
the battery can ONLY be charged from a PAG ACS
charger that is designed to charge PAG Lithium-Ion batteries.
A software upgrade may be required for PAGlok chargers manufactured
prior to November 2008, to enable them to charge the PAG L95e battery.
V-Mount Compatible Model:
the battery can be charged from a PAG
V-Mount compatible charger, such as the PAG V2, PAG V4-iPC and PAG
Cube. A software upgrade may be required for PAGlok or PAG Snap-on
compatible chargers manufactured prior to November 2008, to enable
them to charge the V-Mount L95e via the front PP90 sockets, using
charge adaptor Model 9617.
Snap-on
Compatible Model:
the battery can be charged from an Anton-
Bauer charger that is compatible with Dionic
TM
batteries or from a PAG
ACS charger that is designed to charge PAG Lithium-Ion batteries, e.g.
PAG Pulsar or Quasar chargers. A software upgrade may be required for
PAG chargers manufactured prior to November 2008, to enable them to
charge the PAG L95e battery.
READ THE CHARGER HANDBOOK BEFORE ATTEMPTING TO CHARGE THE
BATTERY.
4.2
Protection Shutdown
IMPORTANT: If the battery is discharged at too high a rate, even
momentarily, it will disconnect its output. This is a safety feature.
It should be noted that even if the nominal consumption of a camera
and light falls within the rating of the battery, high current surges can
occur when the recorder or the light is turned on which may be
sufficient to exceed the rating and trip the protection circuit.
IMPORTANT: A tungsten-filament light draws a high current pulse when
it is turned on from cold, and this may trigger the over-current
protection. This can be avoided by using a suitable light (refer to
Section 3.7 above).
4.3
Battery Output Re-set Procedure
If the battery has been shut down by its protection circuit it can be
recovered by simply removing it from the load and pressing the
display button, provided the battery still retains some charge.
4.4
Thermal Protection
When the battery has been discharged at a high rate it will become
warm, and it is advisable to let it cool before charging it. The battery
should be charged within the temperature range +10°C to +40°C.
4.5
Capacity Indication
A single button-press displays charge status in terms of percentage.
The LEDs light clockwise, from the top right round to top left.
5 LEDs
= 80 - 100%
remaining
4 LEDs
= 60 - 79%
remaining
3 LEDs
= 40 - 59%
remaining
2 LEDs
= 20 - 39%
remaining
1 LED
= 10 - 19%
remaining
1 LED flashing = 0 - 10%
remaining
Instructions for Use
Run-Time Indication:
The display is also capable of indicating an estimate of remaining
run-time, on-load.
The second button-press activates the
time display. The ‘HRS’ LED will flash twice.
The number of hours will be indicated by
the number of lit LEDs: each LED = 1 hour.
The ‘MINS’ LED will then flash twice.
The number of minutes will be indicated by
the number of lit LEDs: each LED = 10 mins.
NOTE: This product provides an estimate of remaining run-time.
A more accurate and sophisticated run-time display is provided by
the PAG Power & Time Display, incorporated in the L95 Time Battery
(Models 9382 PAGlok, 9360 V-Mount and 9383 Snap-on).
5.1
Notwithstanding any provision of any agreement the following
Warranty is exclusive: PAG Limited warrants each PAG L95 battery it
manufactures to be free of defects in material and workmanship under
normal use and service for
18 MONTHS
from the date of purchase.
This warranty extends only to the original purchaser. This warranty
shall not apply to fuses or any product or parts which have been
subject to misuse, neglect, accident or abnormal conditions of
operation.
5.2
In the event of failure of a product covered by this warranty, PAG
Limited will repair and calibrate equipment returned to an authorised
Service Facility within the period of the warranty, provided the
warrantor’s examination discloses to its satisfaction the product was
defective. The warrantor may, at its option, replace the product in lieu
of repair. With regard to any equipment returned within this period,
said repairs or replacements will be made without charge. If the failure
has been caused by misuse, neglect, accident or abnormal conditions
of operation, repairs will be billed at a nominal cost. In such a case,
an estimate will be submitted before work is started, if requested.
5.3
The foregoing Warranty is in lieu of all other warranties, express or
implied, including but not limited to any implied warranty or
merchantability, fitness or adequacy for any particular purpose or use.
PAG Limited shall not be liable for any special, incidental, or
consequential damages, whether in contract, tort, or otherwise.
U5101 ISS B / AUG 2010
PAG Ltd.
UK, 565 Kingston Road, Raynes Park, London SW20 8SA
Tel +44 (0)20 8543 3131 Fax +44 (0)20 8540 4116 E-mail [email protected] Web Site www.paguk.com