background image

5.3 Recall saved readings

The thermometer can store 32 sets of measurement data. When the 

data is full, the last reading will always replace the first.

If you wish to review previous measurement data, when the 

thermometer is shut down, press the Sets button for about 3 

seconds until you see the 

‘M’ symbol

 flicker on the screen, then 

release the button.

When you press the button, you will see the number ‘1’ appear on 

the right side of the screen; this means the first saved reading. The 

number ‘1’ will then disappear quickly and the first saved 

temperature reading will appear. By pressing the button, you can go 

through all the saved temperature readings one by one. After 

reviewing the saved readings, press the button for about 5 seconds 

to automatically save the readings and shut down the thermometer.

5.4 ℃ and ℉ conversion

If you wish to convert ℃ to ℉ or ℉ to ℃, when the thermometer is 

shut down, press the Set button for about 6 seconds until you see 

the 

‘℃’ symbol

 or the 

‘℉’ symbol

 flicker on the screen, then 

release the button. Press the button again and the ℃ symbol or ℉ 

symbol will be converted to the other.

Do not release the button when the “M” symbol appears, but only 

release it when the ‘℃’ symbol or ‘℉’ symbol appears. After 

finishing conversion, press the button for about 5 seconds to 

automatically save the setting and shut down the thermometer.

      Be careful when taking the ear temperature of a child, as their 

ear canals are small.

      When taking the ear temperature of a child aged over 1 year or 

an adult, gently pull the ear up and back to make the ear canal 

straight, allowing the probe to receive infrared rays from the 

eardrum.

!

!

- 10 -

Summary of Contents for PC809

Page 1: ...Medical Infrared Thermometer PC809 PC809EV PC809V Version 2 0 2019 09 01 User s Manual ...

Page 2: ......

Page 3: ...on 0 5 5 Turn on off buzzer speaker vibration 11 5 6 Set threshold for low fever 11 5 7 Set threshold for high fever 2 5 8 Shut down 12 5 9 Replace batteries 12 6 Temperature taking tips 3 7 Cleaning and disinfection 14 7 1 Cleaning 14 7 2 Disinfection 5 8 Troubleshooting 16 9 Specifications 17 10 Symbol descriptions 7 11 Maintenance 8 12 After sales service 18 13 Declaration 18 14 Appendix A EMC In...

Page 4: ...ever necessary Models covered for this manual and their differences are as follows Aside from the above differences the expected use of the three models is exactly the same Note Ear temperature measurement can only be applied to people over the age of 3 months Model PC809 At the end of temperature measurement the buzzer gives a beep cue PC809EV At the end of temperature measurement the speaker broad...

Page 5: ...rature at different sites Therefore readings from different sites should not be directly compared It is very important to tell your doctor which type of thermometer you used and which part of the body you measured Also keep this in mind if you are diagnosing yourself Medical infrared thermometer 1 pc Storage bag 1 pc User s manual 1 pc AAA dry cell battery optional 2 pcs 2 Packing list 3 Product des...

Page 6: ... mode for people of all ages and the ear mode for people above the age of three months 3 3 Principle The infrared temperature sensor collects infrared energy emitted by the eardrum in the ear canal or the skin of the forehead After being focused by a lens the infrared energy is converted into a temperature reading by the thermopiles and measurement circuits 3 ...

Page 7: ...second Accurate and reliable One button design making it easy to operate Both forehead and ear measurement modes 32 memory slots making it easy to save and recall temperatures Switch between Celsius and Fahrenheit Turn on off the buzzer speaker vibration function Orange LED indicates an intelligent low fever alarm Red LED indicates an intelligent high fever alarm Automatic shutdown for energy conse...

Page 8: ...isplay description Fig 5 remove probe cover Probe cover remove it when measuring ear temperature LED display screen Top Cover Label Battery cover Power Measure Set button Infrared sensor Buzzer Speaker outlet Probe 5 ...

Page 9: ... the instrument If damaged never attempt to repair the instrument Please contact the dealer or manufacturer 6 This thermometer consists of high precision parts Do not drop or twist the instrument or infrared sensor Protect it from severe impact and shock 7 Please consult your doctor if you see such symptoms as unexplained irritability vomiting diarrhea dehydration changes in appetite or activity s...

Page 10: ... It is for household use only 12 Clean the thermometer probe after each use 13 Do not use the thermometer on newborns or for continuous temperature monitoring purposes 14 Do not take a measurement while or immediately after nursing a baby 15 Patients should not drink eat bathe or engage in physical activity for 30 minutes before using the thermometer After eating some organs have to work such as t...

Page 11: ...out if you will not use the thermometer for a long time such as over one month Additionally referring to Part 3 in Fig 3 this thermometer has a one button design so when we describe the Power button Measure button and Set button in this manual we are referring to the same button 5 1 Take your forehead temperature Press the Power button to power on Let the probe cover touch the middle of your foreh...

Page 12: ... sure that your forehead is free from hair sweat or dirt Make sure the probe sensor is clean before using the thermome ter Ensure that both the user and thermometer remain in the same room with a stable airflow and a room temperature between 10 0 40 0 50 0 104 0 for at least 30 minutes before using the thermometer 5 2 Take your ear temperature Press the Power button to power on Take off the probe co...

Page 13: ...button for about 5 seconds to automatically save the readings and shut down the thermometer 5 4 and conversion If you wish to convert to or to when the thermometer is shut down press the Set button for about 6 seconds until you see the symbol or the symbol flicker on the screen then release the button Press the button again and the symbol or symbol will be converted to the other Do not release the ...

Page 14: ...wn the thermometer 5 6 Set threshold for low fever This thermometer has 37 5 99 5 preset as an alarm temperature for low fever However 37 5 99 5 is only a reference value At this temperature different people feel different with some feeling uncomfortable and others feeling fine If you do not agree with this low fever threshold after consulting your doctor you can manually change it to suit your own s...

Page 15: ... is from 38 0 100 4 to 38 9 102 0 Once it reaches the Max value press the button again it will return to the Min value and the cycle will repeat After adjustment is complete press the button for about 5 seconds to automatically save the setting and shut down the thermometer 5 8 Shut down When the thermometer is turned on it will shut down automatically when it is not used for 30 seconds You can al...

Page 16: ... has a been lying on one ear or the other b earwax c been exposed to a very hot or very cold environment d just been swimming or bathing In these cases return to normal condition by waiting quietly for 30 minutes before taking the reading If prescription ear drops or other ear medications have been placed in the ear canal use the untreated ear 4 The person to be measured and the thermometer should...

Page 17: ...rous ethanol to clean the infrared sensor lens 7 In the following situations it is recommended to measure 3 5 times in the same location and take the highest temperature as the reading a Newborn infants in the first 100 days b Children under 3 years of age with compromised immune systems c When the user is learning how to use the thermometer for the first time until he she has familiarized him herse...

Page 18: ...aning agents thinners or benzene for cleaning Never immerse any part of the thermometer in liquid or allow liquid to enter the device 7 2 Disinfection Disinfect the thermometer body and the area around the probe with a soft cloth slightly moistened with 75 medical alcohol Do not use the same method to disinfect the infrared sensor as 75 medical alcohol contains water which may damage the lens Do n...

Page 19: ...ve method please contact the dealer or manufacturer 1 First make sure that the probe is clean and free from dirt 2 If the environmental temperature is out of range then both patient and thermometer should stay in a room between 10 0 40 0 50 0 104 0 for at least 30 minutes before taking a temperature measurement 3 If the problem persists after trying the above method please contact the dealer or ma...

Page 20: ... and convertible 32 0 42 9 89 6 109 2 0 2 0 4 0 1 30s 1s 32 saved reading slots See label 5 years 70 g not including batteries 155 38 45 mm Temperature 10 0 40 0 50 0 104 0 Humidity 20 85 RH non condensing Atmospheric pressure 86 106kPa Temperature 20 55 4 131 Humidity 20 93 RH non condensing Atmospheric pressure 86 106 kPa DC 3 0V 2 AAA batteries More than 2 000 measurements Appears on the screen...

Page 21: ...eet the requirements 5 Check for safety risks on a regular basis 6 Remove the batteries if the thermometer will not be used for more than one month Symbol Description SN LOT Type BF applied part Serial number Batch number Please read the instructions carefully Waste electrical materials should be sent to a dedicated collection point for recycling IMPORTANT Inaccurate readings or thermometer damage...

Page 22: ...01 1 2 standard In compliance with ISO10993 1 ISO10993 5 and ISO10993 10 the materials which come into contact with the user are not toxic and have no effect on tissues 14 Appendix A EMC Information Guidance and Manufacturer s Declaration CAUTION This Medical Infrared Thermometer requires special precautions regarding EMC and must be installed and put into service according to the EMC information p...

Page 23: ...ments and those directly connected to the public low voltage power supply network which supplies buildings for domestic purposes Group 1 Class B RF emissions CISPR 11 RF emissions CISPR 11 Guidance and manufacturer s declaration electromagnetic immunity The Medical Infrared Thermometer is intended for use in the electromagnetic environment specified below The customer or user of the device should e...

Page 24: ...ch the thermometer is to be used should be measured to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the thermometer Over the frequency range of 150 kHz to 80 MHz the field strength should be less than 3 V m Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance 80 MHz to 800 MHz ...

Page 25: ...equipment For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer Note 1 At 80 MHz and 800 MHz the separation distance for the higher frequenc...

Page 26: ...ments Co Ltd Add Area B 8 F Building B No 5 Industrial Five Road Jiangbian Community Songgang Subdistrict Bao an District Shenzhen Guangdong 518105 CHINA Tel 86 755 32920339 Email sales888 pacomsz cn 15 Manufacturer information 23 ...

Page 27: ......

Page 28: ......

Reviews: