12. EXPERT OF PROTECTOR FOR
Make sure that the to tal laden power does not exceed the listed maximum output power of the regulator.Be sure to connect the ground point to the ground for your safty.
Page 1: ...VOLTAGE REGULATOR HIGH LOW VOLTAGE PROTECTION Instruction Manual Please read user manual carefully before use S WR 1 0 0 0 V A Input Voltage Microprocessor Control CPU High Low Voltage Protection Outp...
Page 2: ...1 Front Panel 300 500VA Rear Panel 300VA 500VA S WR 5 0 0 V A Input Voltage Microprocessor Control CPU High Low Voltage Protection Output Voltage AUTOMATICVOLTAGEREGULATOR Fuse Input Output 1 OUTPUT V...
Page 3: ...ATOR DELAY UNDELAY SELECTOR POWER SWITCH INPUT VOLTAGE TURBO SELECTOR Front Panel 1000VA 2000VA Rear Panel 1000VA 2000VA FIG 2 S WR 1 0 0 0 V A Input Voltage Microprocessor Control CPU High Low Voltag...
Page 4: ...TAGE METER INPUT VOLTAGE METER DELAYING INDICATOR WORKING INDICATOR UNUSUAL INDICATOR DELAY UNDELAY SELECTOR POWER SWITCH INPUT VOLTAGE TURBO SELECTOR Microprocessor Control CPU High Low Voltage Prote...
Page 5: ...ve only after users notify manufacturer in advance WHEN OUTPUT VOLTAGE OF AVR IS HIGHER THAN SET VALUE THE SYSTEM ENTER INTO HIGH LOW VOLTAGE PROTECTION UNUSUAL RED LED FLASHES EVERY ONE SECOND AND OU...
Page 6: ...ltage and power of the appliance are accord with the labeled power and specification of the unit to avoid any damage Please connect the appliance before turning on the unit Switch on appliance after y...
Page 7: ...ition delay time is 120 seconds When TURBO ON input voltage range is the rated input voltage labeled on the unit When TURBO OFF input voltage range is to be narrowed down 20V NOTE This turbo function...
Page 8: ...ower or higher than labeled voltage AVR will turn into self protection state automatically the UNUSUAL RED indicator flashes every one second and output voltage will be cut off 7 THERMAL PROTECTION 8...
Page 9: ...e automatic voltage regulator and also to the earth terminal of the AC output socket The use of this terminal will depend on your particular installation In any installation heavy duty green insulated...
Page 10: ...neutral line is bonded to earth and there is normally no voltage between them In a stationary land based installation the earth terminal should be connected to a metal earthing stake driven into the g...
Page 11: ...nect all units C check the connected devices D use the unit again unless the problems concerning the connected devices have been solved When in use for a prolonged period of time the AC output may sud...
Page 12: ...f Protector For 12 EXPERT OF PROTECTOR FOR Make sure that the to tal laden power does not exceed the listed maximum output power of the regulator Be sure to connect the ground point to the ground for...
Page 13: ...10 Circuit Protection Circuit Protection 255V 250V AC T5 0A 5x20mm 2 9Kg 1000VA 1500VA 2000VA 250V AC T8 0A 250V AC T10A 250V AC T15A 4 7Kg 5 5Kg 6 7Kg 220V 230V 240V 110V 115V Thermal Protection O 1...
Page 14: ...A 220V 230V 240V 110V 115V SWR 3000VA SWR 5000VA SWR 8KVA SWR 10KVA 39x21 5x26cm 47x28x36 cm Yes Auto operation fan temperature or load 6 secs 120 secs Input Fuse Fuse Size Delay Time Dimension L x W...
Page 15: ...ut power of the regulator For color TV calculate it twice as its listed capacity Make sure that the regulator is of the same output voltage and frequency as the appliance s it connected Make sure that...