background image

INSTALLATION GUIDE

FALC/2 Series LED Area Light

Instructions and specifi cations are subject to change at any time without notice.  Copyright© 2022 PacLights   All Rights Reserved 

Page 3 of 4

Need help?  (800) 988 -6386   Email:  [email protected]  Website:  www.PacLights.com 

PL-INST-FALC/2-v0

FIG. 12

4

Install the FALC/2 to the Arm Mount.  Attach the fi xture Cable to the 
Power Cable (Fig. 12).  Replace the Cover.  Refer to Fig 10.    

FIG. 10

GASKET

FALC/2 FIXTURE

FIG. 11

OPTIONAL ARM MOUNT 

The FALC/2 Arm Mount can be used on either a Round or Square 
Pole.  The drilling template for both the Round and Square Poles is 
shown below (Fig. 8).  Drill holes on the Pole by following the drilling 
template to mount the FALC/2 to the desired height (Fig. 9).   

 

1

FIG. 8

SCREWS

Remove the Screws and the Cover from the Arm Mount prior to 
installation (Fig. 10).  

2

FIG. 9

COVER

ARM MOUNT

Ø 0.375” Clearance 
holes on pole to align 
with Locking Plate 
hole locations

Ø 0.56”x 1.17” Slot to 
run Power Supply Cable 
through the Pole into 
the Arm Mount 

Install the Arm Mount to the Pole with the Gasket.  Place the Locking 
Plate inside the Pole and carefully place the Power Cable through the 
Arm Mount.  Fasten the Bolts and hardware (Fig. 11).   

3

ARM MOUNT

WASHERS

LOCK WASHERS

BOLT

CABLE

POWER CABLE

LOCKING PLATE

WASHERS

LOCK WASHERS

BOLT

POWER CABLE

OPTIONAL ADJUSTABLE ARM MOUNT 

The FALC/2 Adjustable Arm Mount can be used on either a Round 
or Square Pole.  The drilling template for both the Round and Square 
Poles shown below (Fig. 13).  Drill holes on the Pole by following the 
drilling template to mount the FALC/2 to the desired height (Fig. 14).   

 

1

FIG. 13

Install the Adjustable Arm Mount to the Pole with the Gasket.  Place 
the Locking Plate inside the Pole and carefully place the Power Cable 
through the Adjustable Arm Mount.  Fasten the Bolts and hardware 
(Fig. 15).  

2

FIG. 14

Ø 0.375” Clearance 
holes on pole to align 
with Locking Plate 
hole locations

Ø 0.56”x 1.17” Slot to 
run Power Supply Cable 
through the Pole into the 
Adjustable Arm Mount 

FIG. 15

SCREW

COVER

ADJUSTABLE 
ARM MOUNT

WASHER

LOCK WASHER 

BOLT

GASKET

LOCKING PLATE

POLE

Install the FALC/2 fi xture to the Adjustable Arm Mount.  Open the 
Cover by removing the Screw.  Carefully place the fi xture Cable 
through the Adjustable Arm Mount and attach to the Power Cable 
(Fig. 16).  Close the Cover and fasten the Screw when done.  

3

FIG. 16

FALC/2 FIXTURE

POWER CABLE

CABLE

BOLT

WASHER

LOCK WASHER 

POLE

4

The FALC/2 fi xture can be rotated upward by adjusting the Adjustable 
Arm Mount angle.  Loosen the Bolt or remove if necessary.  Set the 
Angle on the side of the Adjustable Arm Mount, then fasten the Bolt 
to secure the Adjustable Arm Mount in place (Fig. 17).     

FALC/2 FIXTURE

ADJUSTABLE 
ARM MOUNT

BOLT

FIG. 17

ANGLES

Summary of Contents for FALC/2 Series

Page 1: ...oper weatherproof function all gaskets must be seated properly and all screws inserted and tightened firmly Apply weatherproof silicone sealant around the edge of the Back Box and or Junction Box This is especially important with an uneven wall surface Silicone all plugs and unused conduit entries FALC 2 150 FALC 2 240 FALC 2 310 Connect the ACL and the ACN from the FALC 2 Fixture to the conduit w...

Page 2: ...r 2 3 8 can be mounted to fit 2 Nominal Round Poles Loosen the Slipfitter Bolts or remove if needed Attach the Power Cable to the Fixture Cable and install the FALC 2 fixture with the Slipfitter onto the Pole Fig 6 Tighten the bolts to secure the Slipfitter to the Pole FIXTURE CABLE FALC 2 FIXTURE FALC 2 FIXTURE SLIPFITTER POLE SLIPFITTER SLIPFITTER BOLT OPTIONAL PHOTOCONTROL FIG 4 The Photocontro...

Page 3: ...PLATE WASHERS LOCK WASHERS BOLT POWER CABLE OPTIONAL ADJUSTABLE ARM MOUNT The FALC 2 Adjustable Arm Mount can be used on either a Round or Square Pole The drilling template for both the Round and Square Poles shown below Fig 13 Drill holes on the Pole by following the drilling template to mount the FALC 2 to the desired height Fig 14 1 FIG 13 Install the Adjustable Arm Mount to the Pole with the G...

Page 4: ... Fixture Cable to the Power Cable Fig 20 3 FIG 20 POWER CABLE TRUNNION MOUNT BOLT WASHER LOCK WASHER FALC 2 FIXTURE CABLE SURFACE WALL 4 The FALC 2 fixture can be rotated upward by adjusting the Trunnion Mount angle Remove the smaller Screws and Nuts and loosen larger ones at each side Rotate to set the angle then fasten the all the Screws and Nuts to secure the Trunnion Mount in place Fig 21 SCRE...