29/78
06/02/2008
1.00
Table for levelling REM tanks
Introduction
The table for levelling your REM milk cooling tank can be found below. In the chapter "Levelling the tank",
you can find how to use the table.
Figure
LR = measuring rod length
LC = inside dimensions milk tank
L = distance between mounting studs of the dipsticks
Table
Type
H2-H1
(mm) 2%
H2-H1
(mm) 5%
LR (mm)
LC (mm)
L (mm)
1050
57
-
876
1279
936
1300
65
-
876
1588
1169
1700
65
-
876
1889
1487
2100
72
-
876
2376
1967
2600
56
-
1175
1777
1372
3100
66
-
1175
2137
1732
3800
74
-
1175
2372
1961
4400
81
-
1175
2742
2331
5000
99
-
1175
3082
2671
6150
87
-
1420
2760
2354
7200
94
98
1420
3218
2817
8200
90
111
1420
3677
3269
9000
95
115
1584
3565
3157
10000
112
117
1584
3912
3504
12000
127
136
1584
4694
4286
15000
166
181
1584
5670
5479
Type = nominal contents of the tank.