![Packeteer PacketSeeker 10000 Manual Download Page 34](http://html.mh-extra.com/html/packeteer/packetseeker-10000/packetseeker-10000_manual_746644034.webp)
Chapter 3: Install into a 8500/9500/10000 Model
3-12
Problems?
Problem
Possible Solution
One of these messages appears
on the Info page or in the LCD:
Upper_inside Interface
Status: Down
(U-In Link Down)
Upper_outside Interface
Status: Down
(U-OutLink Down)
The upper LAN expansion module
is not configured correctly. Check
your cabling.
One of these messages appears
on the Info page or in the LCD:
Lower_inside Interface
Status: Down
(L-In Link Down)
Lower_outside Interface
Status: Down
(L-OutLink Down)
The lower LAN expansion module
is not configured correctly. Check
your cabling.
Since I installed the LAN
expansion module, my unit
cannot see the corporate
network at all.
Are two outside ports connected to
the same hub? The two outside
ports must be connected to
different LANs. Disconnect one of
the outside cables; this should
solve the problem temporarily.
Develop a new strategy for
connecting to two LANs.