Electrical Systems, cont.
Generator Power:
The generator is located under covers in the engine room, port side.
Check Fluids
Check generator fluid levels and the raw water
intake flow:
-
Remove the side cover panel.
-
Check oil and coolant fluid levels.
-
Replace the side cover panel.
-
Check the raw water strainer.
-
Be sure the sea co
Be sure the sea co
Be sure the sea co
Be sure the sea cock is open!
ck is open!
ck is open!
ck is open!
Start Generator
Start the generator from the controls at the bottom
of the electrical panel:
-
Press and hold the rocker switch for 5 or
10 seconds to pre-heat the generator.
-
Then, while continuing to hold down the
preheat rocker switch, press “Start”.
Set Switches
At the electrical panel:
-
Move the slider to cover the “Shore
Power” switch, and turn the “Generator”
switch on.
- Move the slider to cover the “Inverter”
switch and turn the “Transfer” switch on.
-
Turn on individual breakers as needed.
Stop Generator
To stop the generator, turn off all AC loads and
breakers. Then simply press “Stop” on the control
panel.