background image

INTRODUCTION

This carpet extractor is a fully self-contained, portable system.

This machine has a 60 psi solution pump and a one (1) jet spraying system  to apply solution to the carpet.

A 10 inch rotating brush is driven by a cogged belt system at approximately 1000 RPM’s.  This brush provides a very
aggressive agitation of the solution into the carpet fibers to loosen ground-in dirt.  The chevron pattern of the brush bristles
channels the dirty water to the center of the stainless steel vacuum shoe for better extraction.

The two-stage vacuum motor is capable of 80 inches of water lift.  It extracts virtually all of the dirty solution from the carpet
fibers, which dramatically reduces drying time.

This is a very “user friendly”  machine.  It includes a retractable hose to fill the 3 gallon solution tank from almost any faucet.
The 3.5 gallon  recovery tank easily lifts off to dispose of the dirty water.  This machine is easy to handle and store because of
its’ compact size:  10.75” wide X  22.75” long X 26” high, with the handle folded down.

This machine must be grounded.  If it should malfunction or break down,
grounding provides a path of least resistance for electric current to reduce the
risk of electric shock.  This machine is equipped with a cord having an equip-
ment-grounding conductor and grounding plug.  The plug must be inserted
into an appropriate outlet that is properly installed and grounded in accor-
dance with all local codes and ordinances.

WARNING

 - Improper connection of the equipment-grounding conductor

can result in a risk of electric shock.  Check with a qualified electrician or
service person if you are in doubt as to whether the outlet is properly grounded.
Do not modify the plug provided with the machine - if it will not fit the outlet,
have a proper outlet installed by a qualified electrician.

This machine is for use on a nominal 120-volt circuit, and has a grounded
plug that looks like the plug illustrated in figure A.  A temporary adapter that
looks like the adapter illustrated in figures B and C may be used to connect
this plug to a 2-pole receptacle as shown in figure B if a properly grounded
outlet is not available.  The temporary adapter should be used only until a
properly grounded outlet (figure A) can be installed by a qualified electri-
cian.  The green colored rigid ear, lug, or the like extending from the adapter
must be connected to a permanent ground such as a properly grounded outlet
box cover.  Whenever the adapter is used, it must be held in place by a metal
screw.

NOTE: In Canada, the use of a temporary adapter is not permitted by the
Canadian Electrical Code

EXTENSION CORDS

Use only three-wire 14/3 or larger gauge approved extension cords that have
three-prong grounding type plugs and three-pole receptacles that accept the
appliance’s plug.  Replace or repair any damaged cords or plugs.

When servicing, refer to authorized person only.  Use only identical replace-
ment parts.

Grounding Instructions

NOTE:

  Do not use adapters shown in figures B & C in Canada

2

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for DYNAMO

Page 1: ...there is no concealed freight damage If such damage is discovered file a CONCEALED DAMAGE REPORT immediately with the delivering carrier The contents of this manual are based on the latest product inf...

Page 2: ...rdinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or servicepersonifyouareindoubtastowhethertheoutlet...

Page 3: ...at is protected by a ground fault circuit interrupter Consult your electrical contractor 10 To prevent damage to the power cord do not move this machine over the power cord Always lift the power cord...

Page 4: ...n extension cord is not recommended How ever if one is necessary use only a 14 gauge or larger cord Smaller or inferior cords are dangerous and may cause poor performance or damage to your machine 5 A...

Page 5: ...ut 2 Lift the intake filter screen out of the standpipe clean with fresh water and dry then reinstall 3 Flush the solution tank and inlet screen with clean wa ter 4 The handle may be folded down for s...

Page 6: ...5 32 24 33 85 90 36 37 38 39 40 63 64 65 66 11 49 42 48 44 43 41 45 46 47 42 86 87 26 62 60 94 59 54 56 50 53 54 56 57 58 PUMP Access from bottom of machine by removing brush housing then remove 4 pla...

Page 7: ...D Screw 1 4 20 x 3 4 HH SS 4 57 243403 Gasket Vac Shoe 1 58 246606 Plate Vac Shoe 1 59 W311D Washer 4 60 242401 Cuff Hose 2 61 243408 Gasket Pump Plate 1 62 247005 Plate Cover 1 63 245203 Vac Motor 1...

Page 8: ...ing Assembly 7 8 9 10 11 12 13 6 16 17 18 19 21 22 23 24 25 26 27 28 29 30 22 23 8 1 2 3 4 5 6 18 20 14 15 03 01 h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6...

Page 9: ...ng Brush 1 13 W106D Nut 10 24 HEX S S 3 14 W153D2 Screw 10 24x3 4 PHP 4 15 244902 Jet Spray 11004 1 16 W353D Screw 1 4 20x1 2 FHP 2 17 980032 Washer 1 4 Flat Ext 2 18 980075 Washer 3 16 Fender 4 19 W1...

Page 10: ...10 h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Page 11: ...WIRING DIAGRAM WIRING DIAGRAM MACHINE WITH OPTIONAL HOUR METER 11 h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Page 12: ...f unable to locate the Dealer you may contact Pacific Steamex Inc at the address listed herein for the location of the nearest Pacific Steamex Inc repair center or agent or for other instructions pert...

Reviews: