AFX SERIES® OPERATION MANUAL
SECTION 5: UNPACKING AND INSTALLATION
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 95 of 485
Note
AC input, AC Load and sense wiring are
NOT
included with the power source and
must be supplied by the end-user.
Figure 5-27: Parallel Mode Bus Connections using parallel bus cable
5.19.3
Master / Master Paralleling
Two or more masters can be paralleled as well. This allows AFX units to be used separately
or as part of a larger power source system. This operation is the same paralleling using
auxiliary units but only the first Master on the system bus will have an active front panel. All
other Masters will display the fact that they are operating in Auxiliary mode with an inactive
front panel. No re-configuration of the Master unit used in an auxiliary position is needed.